Work Order Procedure (Electric)

1767b-2[1].pdf

Advance of Loan Funds and Budgetary Control and Related Burdens.

Work Order Procedure (Electric)

OMB: 0572-0015

Document [pdf]
Download: pdf | pdf
CROSSARM - See [a]

CLUSTER BRACKET [b]

NO RECORD UNIT

ANCHOR-GUY

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
Single-Phase, Primary Pole-Top Assemblies
M5-2
A1.01
x
M5-18
A1.01P
x
M5-5
A1.011
x
M5-7
A1.011P
x
A1.011L
x
A1.04N
x
A1.04NP
x
A1
A1.1
x
A1A
A1.2
x
A1P
A1.1P
x
A1AP
A1.2P
x
A1.3
x
A1.3P
x
A1.4N
x
A1.5N
x
A1.4NP
x
A1.5NP
x
A1.6N
x
A1.6NP
x
A9-1
A1.11
1
A9-1P
A1.11P
1
A1.12G
G
A2.01
x
A2.01P
x
A2.021
x
A2.021P
x
A2.04N
x
A2.04NP
x
A1-1
A2.1
x
A1-1A
A2.2
x
A1-1P
A2.1P
x
A1-1AP
A2.2P
x
A2
A2.3
x
A2P
A2.3P
x
A2.4N
x
A2.5N
x
A2.4NP
x
A2.5NP
x
A2.6N
x

RETIREMENT UNIT

METER

METER SOCKET (BASE)

AUTO TRANSFORMER

VOLTAGE REGULATOR

TRANFORMER
CAPACITOR

REGULATOR BYPASS SWITCH

CUTOUT ARRESTER - COMB

ARRESTER

CUTOUT

SECTIONALIZER

GANG-OPERATED AB SWITCH
OIL SWITCH WITH CONTROLS

LINE TENSION SWITCH

3 PH OIL CIRCUIT RCLOSER (OCR)
DISCONNECT SWITCH

BY PASS SWITCH (OCR)

1 PH OIL CIRCUIT RECLOSER (OCR)

CUTOUT ARRESTER - COMB

ARRESTER

GROUND
CUTOUT

INSULATOR STRING

CAPACITOR HANGER [c]

PLATFORM

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
368
370
364
365

CURRENT TRANSFORMER

ACCOUNT NUMBER

371

Rev. 06-07
Bulletin 1767B-2
Appendix I
Exhibit A
Page 80

SECURITY LIGHT

POTENTIAL TRANSFORMER

ANCHOR-GUY

PLATFORM

1
1
2
2
2

1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1

CUTOUT

DISCONNECT SWITCH

OIL SWITCH WITH CONTROLS

CAPACITOR

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
A2.6NP
x
A9
A2.21P
2
A9P
A2.21P
2
A3
A3.1
A3.2
A3.3
A3.4
A3.5
A3.6
A3.7
A3.8
A3.9
A4
A4.1
A4.2
M5-24
A5.01
M5-8
A5.02
A5.03
A5
A5.1
A5-2
A5.2
A5.3
A5.4
A5.5
A5.6
A5.7
A5.8
A5.9
A5.2G
G
A5.3NG
G
A5.4NG
G
A7
A5.21
2
A7-1
A5.31
3
A6
A6.1
A6.2
A8
A6.21
2
A6.22G
G
Two-Phase, Primary Pole-Top Assemblies
B1.1N
x
B1.2N
x
B1.1NP
x
B1.2NP
x

RETIREMENT UNIT

ACCOUNT NUMBER

NO RECORD UNIT

CLUSTER BRACKET [b]
CROSSARM - See [a]

CAPACITOR HANGER [c]
INSULATOR STRING
GROUND

ARRESTER
CUTOUT ARRESTER - COMB
1 PH OIL CIRCUIT RECLOSER (OCR)
BY PASS SWITCH (OCR)
3 PH OIL CIRCUIT RCLOSER (OCR)

LINE TENSION SWITCH
GANG-OPERATED AB SWITCH

SECTIONALIZER
CUTOUT
ARRESTER
CUTOUT ARRESTER - COMB
REGULATOR BYPASS SWITCH
TRANFORMER

VOLTAGE REGULATOR
AUTO TRANSFORMER
METER SOCKET (BASE)
METER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER

371

SECURITY LIGHT

Bulletin 1767B-2
Appendix I
Exhibit A
Page 81

Rev. 06-07

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
B1.3N
B1.3NP
B1.4N
B1.5N
B1.4NP
B1.5NP
B1.6N
B1.6NP
B1.7N
B1.8N
B1.7NP
B1.8NP
B1.9N
B1.9NP
B1
B1.11
B1A
B1.12
B1P
B1.11P
B1AP
B1.12P
B1.13
B1.13P
B9-1
B1.14
B9-1P
B1.14P
B2.1N
B2.2N
B2.1NP
B2.2NP
B2.3N
B2.3NP
B2.4N
B2.5N
B2.4NP
B2.5NP
B2.6N
B2.6NP
B2.7N
B2.8N
B2.7NP
B2.8NP
B2.9N
B2.9NP

RETIREMENT UNIT

ACCOUNT NUMBER

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x

NO RECORD UNIT
ANCHOR-GUY

1
1
1
1
1
1
1
1

PLATFORM

CUTOUT

DISCONNECT SWITCH

OIL SWITCH WITH CONTROLS

CAPACITOR

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

CLUSTER BRACKET [b]
CROSSARM - See [a]

CAPACITOR HANGER [c]
INSULATOR STRING
GROUND

ARRESTER
CUTOUT ARRESTER - COMB
1 PH OIL CIRCUIT RECLOSER (OCR)
BY PASS SWITCH (OCR)
3 PH OIL CIRCUIT RCLOSER (OCR)

LINE TENSION SWITCH
GANG-OPERATED AB SWITCH

SECTIONALIZER
CUTOUT
ARRESTER
CUTOUT ARRESTER - COMB
REGULATOR BYPASS SWITCH
TRANFORMER

VOLTAGE REGULATOR
AUTO TRANSFORMER
METER SOCKET (BASE)
METER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER

371

SECURITY LIGHT

Rev. 06-07

Bulletin 1767B-2
Appendix I
Exhibit A
Page 82

ANCHOR-GUY

PLATFORM

2
2
2
2
2
2
2
2
2
2
2
4

2
2
2
2
2
2
2
2
2

CUTOUT

DISCONNECT SWITCH

OIL SWITCH WITH CONTROLS

CAPACITOR

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
B2
B2.21
2
B2P
B2.21P
2
B9
B2.22
2
B9P
B2.22P
2
B1-1
B2.24
2
B1-1A
B2.25
2
B1-1P
B2.24P
2
B1-1AP
B2.25P
2
B3
B3.1
B3.2
B3.3
B3.4
B3.5
B3.6
B3.7
B3.8
B3.9
B4-1
B4.1G
G
B4.2G
G
B5-1
B5.1
B5.2
B5.3
B5.4
B5.5
B5.6
B5.7
B5.8
B5.9
B7
B5.21
2
B7-1
B5.31
2
B8
B6.21
2
Three-Phase, Primary Pole-Top Assemblies
C1.1N
x
C1.2N
x
C1.1NP
x
C1.2NP
x
C1.3N
x
C1.3NP
x
C1.4N
x
C1.5N
x

RETIREMENT UNIT

ACCOUNT NUMBER

NO RECORD UNIT

CLUSTER BRACKET [b]
CROSSARM - See [a]

CAPACITOR HANGER [c]
INSULATOR STRING
GROUND

ARRESTER
CUTOUT ARRESTER - COMB
1 PH OIL CIRCUIT RECLOSER (OCR)
BY PASS SWITCH (OCR)
3 PH OIL CIRCUIT RCLOSER (OCR)

LINE TENSION SWITCH
GANG-OPERATED AB SWITCH

SECTIONALIZER
CUTOUT
ARRESTER
CUTOUT ARRESTER - COMB
REGULATOR BYPASS SWITCH
TRANFORMER

VOLTAGE REGULATOR
AUTO TRANSFORMER
METER SOCKET (BASE)
METER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER

371

SECURITY LIGHT

Rev. 06-07

Bulletin 1767B-2
Appendix I
Exhibit A
Page 83

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
C1.4NP
C1.5NP
C1.6N
C1.6NP
C1.7N
C1.8N
C1.7NP
C1.8NP
C1.9N
C1.9NP
C1
C1.11
C1A
C1.12
C1-2
C1.11L
C1.12L
C1P
C1.11P
C1AP
C1.12P
C1.13
C1-4
C1.13L
C1.13P
C9-1
C1.41
C9-3
C1.41L
C9-1P
C1.41P
C1.81G
C2.1N
C2.2N
C2.3N
C2.3NG
C2.3NP
C2.4N
C2.5N
C2.4NP
C2.5NP
C2.6N
C2.6NP
C2.7N
C2.8N
C2.7NP
C2.8NP
C2.9N
C2.9NP

RETIREMENT UNIT

ACCOUNT NUMBER

G
x
x
x
G
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x

NO RECORD UNIT
ANCHOR-GUY

1
1
1
1
1
1
1
1
1
1
1
1

PLATFORM

CUTOUT

DISCONNECT SWITCH

OIL SWITCH WITH CONTROLS

CAPACITOR

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

CLUSTER BRACKET [b]
CROSSARM - See [a]

CAPACITOR HANGER [c]
INSULATOR STRING
GROUND

ARRESTER
CUTOUT ARRESTER - COMB
1 PH OIL CIRCUIT RECLOSER (OCR)
BY PASS SWITCH (OCR)
3 PH OIL CIRCUIT RCLOSER (OCR)

LINE TENSION SWITCH
GANG-OPERATED AB SWITCH

SECTIONALIZER
CUTOUT
ARRESTER
CUTOUT ARRESTER - COMB
REGULATOR BYPASS SWITCH
TRANFORMER

VOLTAGE REGULATOR
AUTO TRANSFORMER
METER SOCKET (BASE)
METER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER

371

SECURITY LIGHT

Rev. 06-07

Bulletin 1767B-2
Appendix I
Exhibit A
Page 84

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
C2
C2.21
C1-3
C2.21L
C1-3P
C2.21P
C1-1
C2.24
C1-1A
C2.25
C1-1P
C2.24P
C1-1AP
C2.25P
C9
C2.51
C9-2
C2.51L
C9-2PL
C2.51P
C2-1
C2.52
C2-2
C2.52L
C2-2PL
C2.52P
C3
C3.1
C3.2
C3.3
C3.4
C3.5
C3.6
C3.7
C3.8
C3.9
C3-1
C3.1L
C4-1
C4.1G
C4.2G
C5.1
C5-1
C5.2
C5.3
C5.4
C5.5
C5.6
C5.7
C5.8
C5.9
C5.11G
C7
C5.21
C7-1
C5.31
C5.21L
C5.32L
C7-2
C5.22

RETIREMENT UNIT

ACCOUNT NUMBER

G

G
G

NO RECORD UNIT
ANCHOR-GUY

2
3
2
3
2

2
2
2
2
2
2
2
2
2
2
2
2
2

PLATFORM

3
3
3
3
3

3
3
3
3
3
3
3
3
3

3
3
3
3
3
3
3
3
3
3

CUTOUT

DISCONNECT SWITCH

OIL SWITCH WITH CONTROLS

CAPACITOR

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

CLUSTER BRACKET [b]
CROSSARM - See [a]

CAPACITOR HANGER [c]
INSULATOR STRING
GROUND

ARRESTER
CUTOUT ARRESTER - COMB
1 PH OIL CIRCUIT RECLOSER (OCR)
BY PASS SWITCH (OCR)
3 PH OIL CIRCUIT RCLOSER (OCR)

LINE TENSION SWITCH
GANG-OPERATED AB SWITCH

SECTIONALIZER
CUTOUT
ARRESTER
CUTOUT ARRESTER - COMB
REGULATOR BYPASS SWITCH
TRANFORMER

VOLTAGE REGULATOR
AUTO TRANSFORMER
METER SOCKET (BASE)
METER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER

371

SECURITY LIGHT

Bulletin 1767B-2
Appendix I
Exhibit A
Page 85

Rev. 06-07

CROSSARM - See [a]

CLUSTER BRACKET [b]

NO RECORD UNIT

ANCHOR-GUY

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
C5.32
3
C7A
C5.71L [a]
1/2
C5.82G
G
C8
C6.21
2
C6.31
3
C6.21L
2
C8-3
C6.31L
3
C6.52
2
C6.53
3
C6.52G
G
C6.91G
G
Double-Circuit, Primary Pole-Top Assemblies
D1.4N
x
D1.4NP
x
D1.5N
x
D1.5NP
x
DC-C1
D1.81
2
D1.82
2
D1.81L
2
D1.82L
2
D1.81P
2
D1.82P
2
D1.83
2
D1.83L
2
D1.83P
2
D2.9N
x
D2.9NP
x
DC-C2-1
D2.91
4
D2.91L
4
D2.91P
4
D3.1G
G
D4.1G
G
D5.91G
G
DC-C8
D6.91
4
Guy Assemblies
E1-2
E1.1
x
E1-3
E1.1L
x
E3-3
E1.2
x
E1.3L
x
E2-2
E1.4
1

RETIREMENT UNIT

INSULATOR STRING
12

6
6
6
6
6
6

3
3

METER

METER SOCKET (BASE)

AUTO TRANSFORMER

VOLTAGE REGULATOR

TRANFORMER
CAPACITOR

REGULATOR BYPASS SWITCH

CUTOUT ARRESTER - COMB

ARRESTER

CUTOUT

SECTIONALIZER

GANG-OPERATED AB SWITCH
OIL SWITCH WITH CONTROLS

LINE TENSION SWITCH

3 PH OIL CIRCUIT RCLOSER (OCR)
DISCONNECT SWITCH

BY PASS SWITCH (OCR)

1 PH OIL CIRCUIT RECLOSER (OCR)

CUTOUT ARRESTER - COMB

ARRESTER

GROUND
CUTOUT

CAPACITOR HANGER [c]

PLATFORM

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

CURRENT TRANSFORMER

ACCOUNT NUMBER

371

Rev. 06-07
Bulletin 1767B-2
Appendix I
Exhibit A
Page 86

SECURITY LIGHT

POTENTIAL TRANSFORMER

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
E2-3
E1.4L
E1.5
E2.1G
E3.1LG
E4.3LG
Anchor Assemblies
F1-1
F1.6
F1-2
F1.8
F1-3
F1.10
F1-4
F1.12
F1-1S
F2.6
F1-2S
F2.8
F1-3S
F2.10
F1-4S
F2.12
F1-1P
F3.6
F1-2P
F3.8
F1-3P
F3.10
F1-4P
F3.12
F4-1E
F4.1
F4-1S
F4.2
F5-1
F5.1
F5-2
F5.2
F5-3
F5.3
F6-1
F6.6
F6-2
F6.8
F6-3
F6.10
Transformer Assemblies
M27-1A
G1.1G
G1.2G
G105-136
G1.2
G106
G1.3
G1.4
G1.5
G1.6
G9-G39
G1.7
G10
G1.8
G210
G2.1
G2.1G
G310
G3.1
G3.1G

RETIREMENT UNIT

NO RECORD UNIT

G

G

G
G

x
G
G
G

ANCHOR-GUY

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

1

CLUSTER BRACKET [b]
1

1

CROSSARM - See [a]
1

1

CUTOUT
3

1
1
1
1
1
2

ARRESTER
3

1
1
1
1
1
2

CUTOUT ARRESTER - COMB
*

*

TRANFORMER
3

1
1
1
1
1
1
1
2

METER

METER SOCKET (BASE)

AUTO TRANSFORMER

VOLTAGE REGULATOR

CAPACITOR

REGULATOR BYPASS SWITCH

SECTIONALIZER

GANG-OPERATED AB SWITCH
OIL SWITCH WITH CONTROLS

LINE TENSION SWITCH

3 PH OIL CIRCUIT RCLOSER (OCR)
DISCONNECT SWITCH

BY PASS SWITCH (OCR)

1 PH OIL CIRCUIT RECLOSER (OCR)

CUTOUT ARRESTER - COMB

ARRESTER

GROUND
CUTOUT

INSULATOR STRING

CAPACITOR HANGER [c]

PLATFORM

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

CURRENT TRANSFORMER

ACCOUNT NUMBER

371

Rev. 06-07
Bulletin 1767B-2
Appendix I
Exhibit A
Page 87-a

SECURITY LIGHT

POTENTIAL TRANSFORMER

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
G311
G3.2
G3.2G
G312
G3.3
G3.3G
Grounding Assemblies
M2-11
H1.1
M2-13
H2.1
M2-15
H3.1
M2-15A
H4.1
M2-12
H5.1
M2-12A
H5.2
H5.3
Secondary Assemblies
J8
J1.1
J5
J1.2
J10
J2.1
J7-J7C
J2.2
J6-J11
J3.1
J12
J4.1
Service Assemblies
K14C
K1.1
K11C
K1.2
K14-K14L
K1.3
K11-K11L
K1.4
K15C
K1.5
K10-K10L
K2.1
K10C
K2.2
K10C
K2.3
K17-K17L
K3.1
K16C
K3.2
M24
K4.1G
M24-10
K4.2G
Tying Assemblies
M41-1
L1.1
M41-10
L1.2
M42-3
L1.3
M42-21
L1.4
M42-11
L1.5
L2.1
L2.2

RETIREMENT UNIT

NO RECORD UNIT

x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x
G
G

x
x
x
x
x
x

x

G

G

CLUSTER BRACKET [b]
1

1

CROSSARM - See [a]
1

1

GROUND
1
1
1
1
1

1

CUTOUT
3

3

ARRESTER
3

3

CUTOUT ARRESTER - COMB
*

*

TRANFORMER
3

3

METER

METER SOCKET (BASE)

AUTO TRANSFORMER

VOLTAGE REGULATOR

CAPACITOR

REGULATOR BYPASS SWITCH

SECTIONALIZER

GANG-OPERATED AB SWITCH
OIL SWITCH WITH CONTROLS

LINE TENSION SWITCH

3 PH OIL CIRCUIT RCLOSER (OCR)
DISCONNECT SWITCH

BY PASS SWITCH (OCR)

1 PH OIL CIRCUIT RECLOSER (OCR)

CUTOUT ARRESTER - COMB

ARRESTER

CUTOUT

INSULATOR STRING

CAPACITOR HANGER [c]

PLATFORM

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

CURRENT TRANSFORMER

ACCOUNT NUMBER

371

Rev. 06-07
Bulletin 1767B-2
Appendix I
Exhibit A
Page 87-b

SECURITY LIGHT

POTENTIAL TRANSFORMER

ANCHOR-GUY

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
L2.3
L2.4
M42-13
L2.5
M41-1
L3.1
M41-10
L3.2
M42-21
L3.3
M42-3
L3.4
M42-11
L3.5
L3.6
L4.1
L4.2
L4.3
L4.4
Miscellaneous Assemblies
R1
M1.30G [d]
Neutral Assemblies
N1.1
M5-19
N1.2
N1.11
N2.21
N2.1
N2.1L
M5-25
N5.1
N5.2
M5-26
N5.3
N6.1
N6.21
Protection Assemblies
M5-6
P1.01
P1.1
P1.1NG
P1.3
P3.1G
P3.2G
P3.3G
P3.4G
P3.5G
Metering Assemblies
M8
Q1.1
M8-10
Q2.1G

RETIREMENT UNIT

NO RECORD UNIT

G

G
G
G
G
G

G

x
x
x
x
x
x
x
x
x
x
x

G

x
x
x
x
x
x
x
x
x
x
x
x
x

ARRESTER
3

1
1

METER SOCKET (BASE)
1

1

METER

AUTO TRANSFORMER

VOLTAGE REGULATOR

TRANFORMER
CAPACITOR

REGULATOR BYPASS SWITCH

CUTOUT ARRESTER - COMB

ARRESTER

CUTOUT

SECTIONALIZER

GANG-OPERATED AB SWITCH
OIL SWITCH WITH CONTROLS

LINE TENSION SWITCH

3 PH OIL CIRCUIT RCLOSER (OCR)
DISCONNECT SWITCH

BY PASS SWITCH (OCR)

1 PH OIL CIRCUIT RECLOSER (OCR)

CUTOUT ARRESTER - COMB

GROUND
CUTOUT

INSULATOR STRING

CAPACITOR HANGER [c]

CROSSARM - See [a]
PLATFORM

CLUSTER BRACKET [b]

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

1

CURRENT TRANSFORMER

ACCOUNT NUMBER

371

Rev. 06-07
Bulletin 1767B-2
Appendix I
Exhibit A
Page 87-c

SECURITY LIGHT

POTENTIAL TRANSFORMER

ANCHOR-GUY

NO RECORD UNIT

ANCHOR-GUY

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
M8-9
Q2.2G
G
M8-6
Q3.1
M8-12
Q3.2
M8-11
Q3.3
M8-15
Q4.1
Recloser Assemblies
M3-10
R1.1
M3-23A
R1.2
M3-11A
R2.1
M3-12A
R3.1
M3-24A
R2.2
M3-25A
R3.2
M3-30
R3.3
Switching Assemblies
M5-9
S1.01
M5-10
S1.02
S2.01
M3-4
S1.1
S1.1N
S1.3
M3-3B
S2.3
M3-2A
S2.21
M3-3A
S2.31
M3-15
S2.32
M3-41
S3.1
S3.2
Poles and Crossarms Assemblies
M20
W1.1G
G
M19
W2.1G
G
M5-17
W3.1
x
M5-13
W3.2
x
Voltage Ateration Assemblies
M7-11
Y1.1
M7-13
Y1.3 [e]
Y2.1
Y2.2
M9-11
Y3.1
M9-12
Y3.2
M9-13
Y3.3
Y3.4

RETIREMENT UNIT

CLUSTER BRACKET [b]
1
1
1
1

CROSSARM - See [a]
PLATFORM

1
1
1

1
1
1
1
1
1

1
3
2
2

6
4
6
6

2
2
2
2

1

CAPACITOR HANGER [c]
4
6
6

INSULATOR STRING

2
2
5

3

CUTOUT
1
1
1
2
3
3

1

1
1
3

1

1

3

ARRESTER
1
3
2
2
1
2
3
3

1
1

1
1
2
3
2
3
3

3

CUTOUT ARRESTER - COMB
1

1 PH OIL CIRCUIT RECLOSER (OCR)
1
1
2
3
2
3

BY PASS SWITCH (OCR)
2
3
3

3 PH OIL CIRCUIT RCLOSER (OCR)
1

DISCONNECT SWITCH
2
3

1

LINE TENSION SWITCH
3

GANG-OPERATED AB SWITCH
1

OIL SWITCH WITH CONTROLS
3

SECTIONALIZER
1
1

REGULATOR BYPASS SWITCH
1
3

CAPACITOR
1 **
2**
3**
3**

VOLTAGE REGULATOR
1
3

AUTO TRANSFORMER
1
1

METER SOCKET (BASE)
1
1
1

1
1
1

METER

TRANFORMER

CUTOUT ARRESTER - COMB

ARRESTER

CUTOUT

GROUND

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

2
2
2
3

CURRENT TRANSFORMER

ACCOUNT NUMBER
POTENTIAL TRANSFORMER
3

371

Rev. 06-07
Bulletin 1767B-2
Appendix I
Exhibit A
Page 87-d

SECURITY LIGHT

NO RECORD UNIT

1 PH OIL CIRCUIT RECLOSER (OCR)

CUTOUT ARRESTER - COMB

ARRESTER

GROUND
CUTOUT

INSULATOR STRING

CAPACITOR HANGER [c]

CROSSARM - See [a]
PLATFORM

CLUSTER BRACKET [b]

ANCHOR-GUY

SPECIFY QUANTITY & SIZE OF CAPACITORS AS REQUIRED
Y3.1
SINGLE PHASE
Y3.2
TWO PHASE
Y3.3
THREE PHASE
Y3.4
THREE PHASE

BY PASS SWITCH (OCR)

**

DISCONNECT SWITCH

FOR 3-PHASE TRANSFORMER BANKS, CUTOUTS AND ARRESTERS MOUNTED ADJACENT TO ONE ANOTHER MAY BE REPLACED WITH
A COMBINATION CUTOUT AND ARRESTER. SPECIFY TYPE USED.

3 PH OIL CIRCUIT RCLOSER (OCR)

*

LINE TENSION SWITCH

ALTHOUGH UNIT M26-5 WAS NOT A CONSTRUCTION ASSEMBLY (MERELY A GUIDE DRAWING) IN THE PREVIOUS SPECIFICATIONS AND
WAS NOT LISTED IN APPENDIX I, EXHIBIT A OF BULLETIN 1767B-2. IT HAS, HOWEVER, TRADITIONALLY BEEN AFFORDED RECORD UNIT
STATUS AS A SECURITY LIGHT. NO SUCH CONSTRUCTION UNIT EXISTS IN THE REVISED DRAWINGS AND SPECIFICATIONS.

OIL SWITCH WITH CONTROLS

[f]

GANG-OPERATED AB SWITCH

THREE (3) BYPASS ARRESTERS ARE INCLUDED IN THE VOLTAGE REGULATORS BUT ARE NOT CONSIDERED SEPARATE RECORD
UNITS. THE COSTS OF THESE BYPASS ARRESTERS ARE INCLUDED IN THE VOLTAGE REGULATORS.

SECTIONALIZER

[e]

CUTOUT

INITIAL RIGHT-OF-WAY CLEARING & WIDENING COSTS ARE TO BE ALLOCATED TO THE RESPECTIVE CONDUCTOR RECORD UNITS
(ACCOUNT 365) INSTALLED.

ARRESTER

[d]

CUTOUT ARRESTER - COMB

SINGLE AND CLUSTER-TYPE CAPACITOR HANGERS ARE SEPARATE RECORD UNITS. NOTE: RUS BULLETIN 181-2 STIPULATES THAT THIS
RECORD UNIT BE CLASSIFIED IN ACCOUNT 365, OVERHEAD CONDUCTOR AND DEVICES. CAPACITOR HANGERS ARE BEING RE-CLASSIFIED
TO ACCOUNT 364, POLES, TOWERS & FIXTURES, TO BE MORE CONSISTENT WITH THE CLASSIFICATION OF OF TRANSFORMER CLUSTER
BRACKETS.

REGULATOR BYPASS SWITCH

[c]

CAPACITOR

TRANSFORMER CLUSTER BRACKET

TRANFORMER

[b]

VOLTAGE REGULATOR

INCLUDES 1 CROSSARM ASSEMBLY COMPOSED OF 2 CROSSARMS BOLTED TOGETHER. IT SHOULD BE TREATED AS HAVING 2 CROSSARMS
UNLESS THE UTILITY TREATS A CROSSARM ASSEMBLY AS A RECORD UNIT SEPARATE FROM INDIVIDUAL CROSSARMS. IN THAT CASE, THERE
WOULD BE ONLY 1 CROSSARM ASSEMBLY RECORD UNIT.

AUTO TRANSFORMER

[a]

METER SOCKET (BASE)

SUFFIX "G" DENOTES GUIDE DRAWING ONLY. APPLICABLE CONSTRUCTION ASSEMBLIES ARE LISTED SEPARATELY.

G

POTENTIAL TRANSFORMER

G

CONSTRUCTION
ASSEMBLY UNIT
OLD
NEW
Discontinued
M26-5
NONE [f]

RETIREMENT UNIT

METER

RETIREMENT UNIT CONVERSION TABLES FOR 12.47/7.2kV CONSTRUCTION ASSEMBLIES (BULLETIN 1728F-804)
364
365
368
370

CURRENT TRANSFORMER

ACCOUNT NUMBER

1

371

Rev. 06-07
Bulletin 1767B-2
Appendix I
Exhibit A
Page 87-e

SECURITY LIGHT

UG6
UG6B
UG7
UG7B
UG17
UG17B
UG17-2
UG17-2B
UG17-3
UG17-3B

Transformer Assemblies

UA1
UA2
UA3
UB1
UB2
UB3
UB4
UC1
UC2
UC2-1
UC2-2
UC5-1
UC6-1
2
2

2
1

2
1
1

364

1
1
1
1
1

1

1

Primary Terminal Pole Assemblies

CONSTRUCTION
ASSEMBLY UNIT

RETIREMENT UNIT

ACCOUNT NO.

NONE
CROSSARM
MOUNTING BRACKET

3
3
3
3

1
1
1
2
2

CUTOUT
CUTOUT AND
ARRESTER
365

GROUND
RECLOSER
1
1
1
2
2
2
2
3
3
3
3
3
3

1
1
3
3
6
6
3
3

1
1
1
2
2
2
2
3
3
3
3
3
3

367

3
3

Table 1
Distribution Lines - Underground

SURGE ARRESTER
CABLE TERMINATION
ENCLOSURE AND
COVER
INDICATOR, FAULT
ENCLOSURE, PEDESTAL
SECTIONALIZER
SWITCH, DISCONNECT
PADS, TRANSFORMER
REGULATOR, VOLTAGE
368

1
1
1
1
1
1
1
1
1
1

SWITCH, REGULATOR
BYPASS
TRANSFORMER,
PADMOUNTED
CAPACITORS
CONDUIT OR DUCT

369

METER LOOP
PEDESTAL
METER BASE (SOCKET)

370

TRANSFORMER,
CURRENT
TRANSFORMER,
POTENTIAL

Bulletin 1767B-2
Appendix I
Exhibit A
Page 88

Rev. 01-02

NONE

X
X
X
X
X
X
X
X
X
X

CROSSARM

UM3-14
UM3-44
UM3-45
UM3-46
UM3E-1-1A
UM3E-1-1B
UM3E-1-1C
UM3E-1-1D
UM3E-1-1E
UM3E-1-1F
UM3E-1-1G

Sectionalizing Assemblies

UJ1-2
UJ1-3
UJ1-4
UJ1-6
UJ1-8
UJ2-1
UJ2-2
UJ2-4
UJ2-6
UJ2-8
UK5
UK6
Pad Assemblies
UM1-5C
UM1-5NC
UM1-6C
UM1-7C
UM1-7NC

Secondary Assemblies

CONSTRUCTION
ASSEMBLY UNIT

RETIREMENT UNIT

GROUND

RECLOSER
1
1
3

ENCLOSURE AND
COVER
1
1
1
1

367
INDICATOR, FAULT

365
ENCLOSURE, PEDESTAL
1
1
1
1
1
1
1

SECTIONALIZER
1
1

PADS, TRANSFORMER
A/R
A/R
A/R
A/R
A/R

368
SWITCH, REGULATOR
BYPASS
TRANSFORMER,
PADMOUNTED

364

369

METER LOOP

ACCOUNT NO.

PEDESTAL
1
1

370
TRANSFORMER,
CURRENT
TRANSFORMER,
POTENTIAL

SWITCH, DISCONNECT

CABLE TERMINATION

SURGE ARRESTER

CUTOUT AND
ARRESTER

CUTOUT

MOUNTING BRACKET

Table 1
Distribution Lines - Underground
Rev. 01-02

Bulletin 1767B-2
Appendix I
Exhibit A
Page 89

METER BASE (SOCKET)

CONDUIT OR DUCT

CAPACITORS

REGULATOR, VOLTAGE

SURGE ARRESTER

RECLOSER

CUTOUT AND
ARRESTER

CUTOUT

MOUNTING BRACKET

CROSSARM

NONE

1
1
1
1
1
1

CABLE TERMINATION

UM3E-3-10
UM3E-3-10A
UM3E-3-11
UM3E-3-11A
UM3E-3-12
UM3E-3-12A

ENCLOSURE AND
COVER

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

ENCLOSURE, PEDESTAL

Sectionalizing Assemblies (cont.)
UM3E-2-2A
UM3E-2-2B
UM3E-2-2C
UM3E-2-2D
UM3E-2-2E
UM3E-2-2F
UM3E-3-3B
UM3E-3-3C
UM3E-3-3D
UM3E-3-3E
UM3E-3-3F
UM3E-3-3
UM3E-3-3A
UM3E-3-4
UM3E-3-4A
UM3E-3-5
UM3E-3-5A
UM3E-3-6
UM3E-3-6A
UM3E-3-7
UM3E-3-7A
UM3E-3-8
UM3E-3-8A
UM3E-3-9
UM3E-3-9A

CONSTRUCTION
ASSEMBLY UNIT

RETIREMENT UNIT

GROUND

367
INDICATOR, FAULT

365

368
SWITCH, REGULATOR
BYPASS
TRANSFORMER,
PADMOUNTED

364

369

METER LOOP

ACCOUNT NO.
370
TRANSFORMER,
CURRENT
TRANSFORMER,
POTENTIAL

PADS, TRANSFORMER

SWITCH, DISCONNECT

SECTIONALIZER

Table 1
Distribution Lines - Underground
Rev. 01-02

Bulletin 1767B-2
Appendix I
Exhibit A
Page 90

METER BASE (SOCKET)
PEDESTAL

CONDUIT OR DUCT

CAPACITORS

REGULATOR, VOLTAGE

CUTOUT

MOUNTING BRACKET

CROSSARM

NONE

Sectionalizing Assemblies (cont.)
UM3E-3-13
UM3E-3-13A
UM3E-3-14
UM3E-3-14A
UM3E-3-19
UM3E-3-19A
Secondary Terminal Pole Assemblies
UM5
X
UM5-6
UM5-6A
Miscellaneous Accessories
UM6-1
X
UM6-2
UM6-3
UM6-4
UM6-5
X
UM6-6
UM6-7
X
UM6-8
X
UM6-9
X
UM6-10
X
UM6-11
X
UM6-12
X
UM6-13
X
UM6-14
X
UM6-15
X
UM6-17
X
UM6-18
X
UM6-19
X
UM6-20
X

CONSTRUCTION
ASSEMBLY UNIT

RETIREMENT UNIT

A/R

GROUND

CABLE TERMINATION
A/R
A/R

367

A/R

INDICATOR, FAULT

365
ENCLOSURE, PEDESTAL
1
1
1
1
1
1

368
SWITCH, REGULATOR
BYPASS
TRANSFORMER,
PADMOUNTED

364
CONDUIT OR DUCT
A/R
A/R

369

METER LOOP

ACCOUNT NO.
370
TRANSFORMER,
CURRENT
TRANSFORMER,
POTENTIAL

PADS, TRANSFORMER

SWITCH, DISCONNECT

SECTIONALIZER

ENCLOSURE AND
COVER

SURGE ARRESTER

RECLOSER

CUTOUT AND
ARRESTER

Table 1
Distribution Lines - Underground
Rev. 01-02

Bulletin 1767B-2
Appendix I
Exhibit A
Page 91

METER BASE (SOCKET)
PEDESTAL

CAPACITORS

REGULATOR, VOLTAGE

CUTOUT AND
ARRESTER

CUTOUT

MOUNTING BRACKET

CROSSARM

NONE

UM8
UM8-2
UM8-3
UM8-3A
UM8-4
UM8-4A
UM8-5
UM8-6
UM8-7-A
UM8-7-B
UM8-7-C

Metering Assemblies

UM7-1

Regulator Assembly

1

Miscellaneous Accessories (cont.)
UM6-21
X
UM6-22
X
UM6-24
UM6-26
UM6-28 GUIDE DWG.
UM6-32 GUIDE DWG.
UM6-33
UM6-34
UM6-35
A/R
UM6-36
A/R
UM6-37
UM6-38
UM6-39 GUIDE DWG.

CONSTRUCTION
ASSEMBLY UNIT

RETIREMENT UNIT

GROUND

SURGE ARRESTER
1

A/R
A/R

A/R
A/R

CABLE TERMINATION
2

A/R
A/R

367
INDICATOR, FAULT

365
REGULATOR, VOLTAGE
1

368

A/R

1

SWITCH, REGULATOR
BYPASS
TRANSFORMER,
PADMOUNTED

364
CONDUIT OR DUCT
A/R
A/R
A/R
A/R

A/R
A/R

A/R
A/R

369

1
1
1
1

1
1
1
1

METER LOOP

ACCOUNT NO.
METER BASE (SOCKET)
1
1
1
1

1
1
1
1
A/R
A/R

370

A/R
A/R
A/R
A/R

A/R
A/R
A/R
A/R

TRANSFORMER,
CURRENT
TRANSFORMER,
POTENTIAL

PADS, TRANSFORMER

SWITCH, DISCONNECT

SECTIONALIZER

ENCLOSURE, PEDESTAL

ENCLOSURE AND
COVER

RECLOSER

Table 1
Distribution Lines - Underground
Rev. 01-02

Bulletin 1767B-2
Appendix I
Exhibit A
Page 92

PEDESTAL

CAPACITORS

CROSSARM

NONE

X

X

X

MOUNTING BRACKET

UR2
UR2-1
UR2-2
UR2-3
UR2-4
UR2-5
UR2-NT
UR2-ST

X
X
X
X
X
X
X
X

Conduit and Trenching Assemblies

UM48-1
UM48-2
UM48-3
UM48-4
UM48-5
UM48-6

Grounding Assemblies

UM33

Sectionalizing Assembly

UM27-1
UM27-2
UM27-3
UM28

Corrosion Control Assemblies

UM9-2
UM12

Miscellaneous Assemblies

CONSTRUCTION
ASSEMBLY UNIT

RETIREMENT UNIT

A/R
A/R
A/R
A/R
4
A/R

A/R
1

GROUND

ENCLOSURE AND
COVER
1

1

367
INDICATOR, FAULT

365
SWITCH, DISCONNECT
3

368
SWITCH, REGULATOR
BYPASS
TRANSFORMER,
PADMOUNTED

364

CAPACITORS
6

369

METER LOOP

ACCOUNT NO.
370

1

TRANSFORMER,
CURRENT
TRANSFORMER,
POTENTIAL

PADS, TRANSFORMER

SECTIONALIZER

ENCLOSURE, PEDESTAL

CABLE TERMINATION

SURGE ARRESTER

RECLOSER

CUTOUT AND
ARRESTER

CUTOUT

Table 1
Distribution Lines - Underground
Rev. 01-02

Bulletin 1767B-2
Appendix I
Exhibit A
Page 93

METER BASE (SOCKET)
PEDESTAL

CONDUIT OR DUCT

REGULATOR, VOLTAGE

364

1

365

1
1

367

1

Table 1
Distribution Lines - Underground

A/R - As Required
* - If these units are built to the specifications, then referenced retirement unit should be used.

UX1 GUIDE DWG.
UX2
*
UX3
*
UX4 GUIDE DWG.
UX5 GUIDE DWG.
UX7 GUIDE DWG.
UX8 GUIDE DWG.
UX11 GUIDE DWG.

Guideline Drawings

CONSTRUCTION
ASSEMBLY UNIT

RETIREMENT UNIT

ACCOUNT NO.

NONE
CROSSARM
MOUNTING BRACKET
CUTOUT
CUTOUT AND
ARRESTER
GROUND
RECLOSER
SURGE ARRESTER
CABLE TERMINATION
ENCLOSURE AND
COVER
INDICATOR, FAULT
ENCLOSURE, PEDESTAL
SECTIONALIZER
SWITCH, DISCONNECT
PADS, TRANSFORMER
REGULATOR, VOLTAGE
368

SWITCH, REGULATOR
BYPASS
TRANSFORMER,
PADMOUNTED
CAPACITORS
CONDUIT OR DUCT

369

METER LOOP
PEDESTAL
METER BASE (SOCKET)

370

TRANSFORMER,
CURRENT
TRANSFORMER,
POTENTIAL

Bulletin 1767B-2
Appendix I
Exhibit A
Page 94

Rev. 01-02

Rev. 01-02

Table 2
14.4/24.9 kV Distribution Lines - Overhead
365

STRING of
INSULATORS

CROSSARM

RETIREMENT UNIT

364

NONE

ACCOUNT NO.

Bulletin 1767B-2
Appendix I
Exhibit B
Page 95

CONSTRUCTION
ASSEMBLY UNIT

Bulletin 50-5
(D-803)

Single Phase Primary Pole Top Assembly Units
VA1.01
VA1.01P
VA1.011
VA1.011P
VA1.011L
VA1.1
VA1.2
VA1.1P
VA1.2P
VA1.3
VA1.3P
VA1.11
VA1.11P
VA1.12G
VA2.01
VA2.01P
VA2.021
VA2.021P
VA2.1
VA2.1P
VA2.21
VA2.21P
VA3.1
VA3.2
VA3.3
VA4.1
VA4.2
VA5.1
VA5.2
VA5.3
VA5.4
VA5.5G
VA5.21

X
X
X
X
X
X
X
X
X
X
X

VM5-2
M5-18
VM5-5
VM5-7
VA1
VAIA

1
1

VA9-1

GUIDE DWG.
X
X
X
X
X
X

VA2
2
2

VA9
1
1
1
2
2
1
1
1
1

VA3
VA4
VA5
VA5-2
VA5-3

GUIDE DWG.
2

1

VA7

Rev. 01-02

Table 2
14.4/24.9 kV Distribution Lines - Overhead
365

STRING of
INSULATORS

CROSSARM

RETIREMENT UNIT

364

NONE

ACCOUNT NO.

Bulletin 1767B-2
Appendix I
Exhibit B
Page 96

CONSTRUCTION
ASSEMBLY UNIT

Bulletin 50-5
(D-803)

Single Phase Primary Pole Top Assembly Units (cont.)
VA5.31
3
VA6.1
VA6.2
VA6.21
2
VA6.22G
GUIDE DWG.

1
2
2
2

VA7-1

VA8

Two Phase Primary Pole Top Assembly Units
VB1.11
VB1.12
VB1.11P
VB1.12P
VB1.13
VB1.13P
VB1.14
VB1.41
VB1.14P
VB1.41P
VB2.21
VB2.21P
VB2.22
VB2.51
VB2.22P
VB2.51P
VB3.1
VB4.1
VB5.1
VB5.21
VB5.31
VB6.21
VC1.11
VC1.12
VC1.11L
VC1.12L
VC1.11P
VC1.12P
VC1.13
VC1.13L

1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2

2
3
2
1
1
1
1
1
1
1
1

VB1
VB1A

VB9-1

VB2
VB9

2
4
2
2
2
4

VB3
VB4-1
VB5-1
VB7
VB7-1
VB8
VC1
VC1B
VC1-2

VC1-4

Rev. 01-02

Table 2
14.4/24.9 kV Distribution Lines - Overhead
365

STRING of
INSULATORS

CROSSARM

RETIREMENT UNIT

364

NONE

ACCOUNT NO.

CONSTRUCTION
ASSEMBLY UNIT
Three Phase Primary Pole Top Assembly Units (cont.)
VC1.13P
1
VC1.41
1
VC1.41L
1
VC1.41P
1
VC1.81G
GUIDE DWG.
VC2.21
2
VC2.21L
2
VC2.21P
2
VC2.51
2
VC2.51L
2
VC2.51P
2
VC2.52
2
VC2.52L
2
VC2.52P
2
VC3.1
VC3.2L
VC4.1
VC4.2L
VC5.1
VC5.2L
VC5.11G
GUIDE DWG.
VC5.21
2
VC5.31
3
VC5.71L
1
VC5.82G
GUIDE DWG.
VC6.21
2
VC6.31
3
VC6.51
2
VC6.52G
GUIDE DWG.
VC6.91G
GUIDE DWG.
Double Circuit Primary Pole Top Assembly Units
VD1.81
2
VD1.82
2
VD1.81L
2
VD1.82L
2
VD1.81P
2
VD1.82P
2
VD1.83
2

Bulletin 1767B-2
Appendix I
Exhibit B
Page 97

Bulletin 50-5
(D-803)

VC9-1
VC9-3

VC2
VC1-3
VC9
VC9-2
VC2-1
VC2-2
3
3
6
6
3
3

VC3
VC3-1
VC4-1
VC4-1L
VC5-1
VC5-1L

3
3
3

VC7
VC7-1

6
6
6

VC8

VDC-C1

Rev. 01-02

Table 2
14.4/24.9 kV Distribution Lines - Overhead
365

STRING of
INSULATORS

CROSSARM

RETIREMENT UNIT

364

NONE

ACCOUNT NO.

Bulletin 1767B-2
Appendix I
Exhibit B
Page 98

CONSTRUCTION
ASSEMBLY UNIT

Bulletin 50-5
(D-803)

Double Circuit Primary Pole Top Assembly Units (cont.)
VD1.83L
VD1.83P
VD2.91
VD2.91L
VD2.91P
VD3.1G
VD4.1G
VD5.91G
VD6.91

2
2
4
4
4

VDC-C1L
VDC-C2-1
VDC-C2-1L

GUIDE DWG.
GUIDE DWG.
GUIDE DWG.
4

12

Rev. 01-02

Table 2
14.4/24.9 kV Distribution Line - Overhead

ANCHOR GUY
ASSEMBLY

RETIREMENT UNIT

364

NONE

ACCOUNT NO.

Bulletin 1767B-2
Appendix I
Exhibit B
Page 99

CONSTRUCTION
ASSEMBLY UNIT

Bulletin 50-5
(D-803)

Guying Assembly Units
E1.1
E1.01
E2.01
E2.1
E2.2G
E2.3G
E3.1
E4.1L
E4.4LG
E5.1G

X
1
1
X
GUIDE DWG.
GUIDE DWG.
X
X
GUIDE DWG.
GUIDE DWG.

VE1-2
E2-2
VE1-3

E3-3

Anchor Assembly Units
F1.6
F1.8
F1.10
F1.12
F2.6
F2.8
F2.10
F2.12
F3.6
F3.8
F3.10
F3.12
F4.1
F4.2
F5.1
F5.2
F5.3
F6.6
F6.8
F6.10

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

F1-1
F1-2
F1-3
F1-4
F1-1S
F1-2S
F1-3S
F1-4S
F1-1P
F1-2P
F1-3P
F1-4P
F4-1E
F4-1S
F5-1
F5-2
F5-3
F6-1
F6-2
F6-3

Bulletin 1767B-2
Appendix I
Exhibit B
Page 99a

Rev. 01-02

Table 2
14.4/24.9 kV Distribution Line - Overhead

TRANSFORMER

CUTOUT

368
ARRESTER, SURGE

GROUND

365

BRACKET,
TRANSFORMER
CLUSTER

364

CROSSARM

RETIREMENT UNIT

NONE

ACCOUNT NO.

CONSTRUCTION
ASSEMBLY UNIT

Bulletin 50-5
(D-803)

Transformer Assembly Units
G1.1G
VG1.2
VG1.3
VG1.4
VG1.5
VG1.6
VG1.7
VG1.8
VG2.1
G2.1G
VG3.1
G3.1G
VG3.2
G3.2G
VG3.3
G3.3G

GUIDE DWG.

1
1
1
1
1
2

1
1
1
1
1
1
1
2

M27-1
VG105
VG106

1

1

1
1
1
1
1
2

1

1

3

3

3

VG310

1

1

3

3

3

VG311

1

1

3

3

3

VG312

VG19
VG10
VG210

GUIDE DWG.
GUIDE DWG.
GUIDE DWG.
GUIDE DWG.

Grounding Assembly Units
H1.1
H2.1
H3.1
H4.1

1
1
1
1

VM2-11

M2-15

Secondary Assembly Units
J1.1
J1.2
J2.1
J2.2
J3.1
J4.1

X
X
X
X
X
X

J8
J5
J10
J7
J6
J12

Rev. 01-02

Table 2
14.4/24.9 kV Distribution Line - Overhead

Bulletin 1767B-2
Appendix I
Exhibit B
Page 99b

RETIREMENT UNIT

NONE

ACCOUNT NO.

CONSTRUCTION
ASSEMBLY UNIT

Bulletin 50-5
(D-803)

Service Assembly Units
K1.1
X
K1.2
X
K1.3
X
K1.4
X
K2.1
X
K2.2
X
K2.3
X
K3.1
X
K3.2
X
K4.1G
GUIDE DWG.
K4.2G
GUIDE DWG.
K4.3G
GUIDE DWG.
K4.4G
GUIDE DWG.
Tying Guides
VL1.1G
GUIDE DWG.
VL1.2G
GUIDE DWG.
L2.1G
GUIDE DWG.
L2.2G
GUIDE DWG.
L3.1G
GUIDE DWG.
L3.2G
GUIDE DWG.
L3.3G
GUIDE DWG.
L4.1G
GUIDE DWG.
L4.2G
GUIDE DWG.
Miscellaneous Assembly Units and Guides
M1.30G
GUIDE DWG.
Neutral Assembly Units
N1.1
X
N1.2
X
N1.11
X
N2.21
X
N2.1
X
N2.1L
X
N3.1
X
N5.1
X
N5.2
X
N6.1
X
N6.21
X

K14
K11C
K11
K15C
K10
K10C
K17L
K16C
M24
M24-10
M8-10
M8-9

R1

M5-19

Bulletin 1767B-2
Appendix I
Exhibit B
Page 99c

Rev. 01-02

Table 2
14.4/24.9 Kv Distribution Line - Overhead

TRANSFORMER,
CURRENT

METER SOCKET

METER

CUTOUT

370
TRANSFORMER,
POTENTIAL

365
ARRESTER, SURGE

NONE

RETIREMENT UNIT

CROSSARM

364

ACCOUNT NO.

CONSTRUCTION
ASSEMBLY UNIT

Bulletin 50-5
(D-803)

Protection Assembly Units
VP1.01
VP1.1
VP1.3
P2.1
P2.2
P2.3
VP3.1G
VP3.2G
VP3.3G

1
1
3

VM5-6

X
X
X
GUIDE DWG.
GUIDE DWG.
GUIDE DWG.

VM2-12
VM2-12A
VM2-12A2

Metering Assembly Units
Q1.1
Q3.1
Q3.2
Q3.3
VQ4.1

3

3

3

1
1
1
1
1

1
1
1
1
1

3

1
2
2
2
3

M8
M8-6
M8-12
M8-11

Bulletin 1767B-2
Appendix I
Exhibit B
Page 99d

Rev. 01-02

Table 2
14.4/24.9 kV Distribution Line - Overhead

CONSTRUCTION
ASSEMBLY UNIT
Oil Circuit Recloser Assembly Units
VR1.1
VR1.2
VR2.1
1
VR3.1
1
VR2.2
1
VR3.2
1
Sectionalizing Assembly Units
VS1.01
VS1.02
VS2.01
VS1.1
VS1.3
VS2.21
VS2.31
VS2.32
Wood Poles, Crossarms and Braces
W1.1G
GUIDE DWG.
W2.1G
GUIDE DWG.
W3.1
X
W3.2
X

SWITCH/DISCONNECT
DEVICE

GROUP OPERATED
SWITCH

RECLOSER BYPASS
SWITCH

RECLOSER, OIL
CIRCUIT

STRING OF
INSULATORS

CUTOUT/ARRESTER
COMBINATION

CUTOUT

ARRESTER

365

CROSSARM

BRACKET,
TRANSFORMER
CLUSTER

RETIREMENT UNIT

364

NONE

ACCOUNT NO.

Bulletin 50-5
(D-803)

2
2

1
1
2
3
2
3

1

4
6

1
1
2
3
2
3

VM3-10A
VM3-19A
VM3-20A
VM3-25A
VM3-24A

2
3

1

M5-9
M5-10

1
1
1
3
2
2
2

VM3-4
4
6
6

2
3
1

VM3-2
VM3-3
VM3-16
M20
M19
M5-17
M5-13

Bulletin 1767B-2
Appendix I
Exhibit B
Page 99e

Rev. 01-02

Table 2
14.4/24.9 kV Distribution Line - Overhead

TRANSFORMER
(AUTO)

VOLTAGE
REGULATOR, STEP
TYPE

REGULATOR BYPASS
SWITCH

CUTOUT

CAPACITOR HANGER,
CLUSTER TYPE

STRING OF
INSULATORS

CAPACITOR

368

365
ARRESTER, SURGE

REGULATOR
PLATFORM

RETIREMENT UNIT

364

CROSSARM

ACCOUNT NO.

CONSTRUCTION
ASSEMBLY UNIT

Bulletin 50-5
(D-803)

Voltage Alteration Equipment Assembly Units
VY1.1
VY1.3
VY2.1
VY3.2
VY3.3

1
1
1

1
3
2
2
3

1
3
2

1
3
1
1

1
2
3

1
3

VM7-3
1

A/R
A/R


File Typeapplication/pdf
File Title1767B-1.pdf
AuthorAMiller
File Modified2012-01-24
File Created2005-06-22

© 2024 OMB.report | Privacy Policy