| UNITED STATES DEPARTMENT OF AGRICULTURE |
|
|||||||||||||||
| FEDERAL GRAIN INSPECTION SERVICE | ||||||||||||||||
| TESTWEIGHT CHECKTEST | ||||||||||||||||
| NOTE: TEST UNIT OPERATOR FILL IN SHADED AREAS ONLY | ||||||||||||||||
| DATE MAILED | FIELD OFFICE | AGENCY | LOCATION | |||||||||||||
| SCALE / BEAM TEST | ||||||||||||||||
Before proceeding with test review Chapter 5 of the Equipment Handbook. Clean, level and balance the scale, filling apparatus, and kettle. Test weights must have a current Class F Report of Test. |
||||||||||||||||
| Scale Brand / Model / Serial No. / Date of Test | ||||||||||||||||
| Scale Test for Electronic or Mechanical Grain Scales: This scale was tested in accordance with Chapter 2 of the Equipment Handbook and found to be within tolerance. | ||||||||||||||||
| Beam Test: Complete test below. Tolerance is +/- 0.10 pound. | ||||||||||||||||
| Load | Beam | Load | Beam | Load | Beam | Sensitivity | Beam Response | |||||||||
| g | lb | Reading |
Error | g | lb | Reading |
Error | g | lb | Reading |
Error | @ 60 lb/bu |
OK? |
|||
| 0 | 0 | 142 | 10 | 850 | 60 | g | lb | YES | NO | |||||||
| 71 | 5 | 425 | 30 | 850+1 g | 60+1g | |||||||||||
| GRAIN TEST | ||||||||||||||||
| Before the Grain Test, check alignment of the funnel and kettle. Record results to 0.00 pound for mechanical or electronic scales. For beams, the 0.1 pound graduations should be | ||||||||||||||||
| estimated to ¼ graduations and recorded as 0.025, 0.050, 0.075, or 0.100 pounds. For each sample, strike the highest and lowest drops and average the remaining three results. | ||||||||||||||||
| TEST UNIT Beam / Filler Brand & Serial No. | STANDARD UNIT Beam / Filler Brand & Serial No. | TEST SUMMARY | ||||||||||||||
| Kettle Brand & Serial No. | Kettle Brand & Serial No. | |||||||||||||||
| Drop | Sample 1 | Sample 2 | Sample 3 | Drop | Sample 1 | Sample 2 | Sample 3 | Sample 1 | Sample 2 | Sample 3 | TOTAL | |||||
| 1 | 1 | TEST UNIT | 0.000 | 0.000 | 0.000 | 0.000 | ||||||||||
| 2 | 2 | STD. UNIT | 0.000 | 0.000 | 0.000 | 0.000 | ||||||||||
| 3 | 3 | DIFFERENCE | 0.000 | 0.000 | 0.000 | 0.000 | ||||||||||
| 4 | 4 | Mean Deviation from Standard (Total Diff. 3) | ||||||||||||||
| 5 | 5 | MDS Tolerance = 0.15 lb / bu | ||||||||||||||
| AVERAGE | AVERAGE | OUT OF TOLERANCE | ||||||||||||||
| Results By: | Date: | Results By: | Date: | Remarks | ||||||||||||
| VOLUME TEST | ||||||||||||||||
| Scale Used in Test / Brand / Model / Serial No. | Kettle Brand & Serial No. | Results By: / Date of Test: | ||||||||||||||
| GROSS - TARE = NET WEIGHT (1,098.08 g at 68 °F) | OR Filled kettle ± 1.0 g of Standard counter weight. | |||||||||||||||
| Form FGIS-927 (03/25) Previous editions are obsolete. Expires 03/28 | ||||||||||||||||
| UNITED STATES DEPARTMENT OF AGRICULTURE |
|
||||||||||||||
| FEDERAL GRAIN INSPECTION SERVICE | |||||||||||||||
| TESTWEIGHT CHECKTEST | |||||||||||||||
| NOTE: TEST UNIT OPERATOR FILL IN SHADED AREAS ONLY | |||||||||||||||
| DATE MAILED | FIELD OFFICE | AGENCY | LOCATION | ||||||||||||
| 1 | 2 | 3 | 4 | ||||||||||||
| SCALE / BEAM TEST | |||||||||||||||
Before proceeding with test review Chapter 5 of the Equipment Handbook. Clean, level and balance the scale, filling apparatus, and kettle. Test weights must have a current Class F Report of Test. |
|||||||||||||||
| Scale Brand / Model / Serial No. / Date of Test | |||||||||||||||
| 5a | |||||||||||||||
| Scale Test for Electronic or Mechanical Grain Scales: This scale was tested in accordance with Chapter 2 of the Equipment Handbook and found to be within tolerance. | |||||||||||||||
| Beam Test: Complete test below. Tolerance is +/- 0.10 pound. | |||||||||||||||
| Load | Beam | 5b | Load | Beam | Load | Beam | Sensitivity | Beam Response | |||||||
| g | lb | Reading |
Error | g | lb | Reading |
Error | g | lb | Reading |
Error | @ 60 lb/bu |
OK? |
||
| 0 | 0 | 142 | 10 | 850 | 60 | g | lb | YES | NO | ||||||
| 71 | 5 | 425 | 30 | 850+1 g | 60+1g | ||||||||||
| GRAIN TEST | |||||||||||||||
| Before the Grain Test, check alignment of the funnel and kettle. Record results to 0.00 pound for mechanical or electronic scales. For beams, the 0.1 pound graduations should be | |||||||||||||||
| estimated to ¼ graduations and recorded as 0.025, 0.050, 0.075, or 0.100 pounds. For each sample, strike the highest and lowest drops and average the remaining three results. | |||||||||||||||
| TEST UNIT Beam / Filler Brand & Serial No. | STANDARD UNIT Beam / Filler Brand & Serial No. | TEST SUMMARY | |||||||||||||
| 6a | 6d | ||||||||||||||
| Kettle Brand & Serial No. | Kettle Brand & Serial No. | ||||||||||||||
| Drop | Sample 1 | Sample 2 | Sample 3 | Drop | Sample 1 | Sample 2 | Sample 3 | Sample 1 | Sample 2 | Sample 3 | TOTAL | ||||
| 1 | 6b | 1 | 6e | TEST UNIT | 6c | 0.000 | 0.000 | 0.000 | |||||||
| 2 | 2 | STD. UNIT | 0.000 | 0.000 | 0.000 | 0.000 | |||||||||
| 3 | 3 | DIFFERENCE | #VALUE! | 0.000 | 0.000 | 0.000 | |||||||||
| 4 | 4 | Mean Deviation from Standard (Total Diff. 3) | |||||||||||||
| 5 | 5 | MDS Tolerance = 0.15 lb / bu | |||||||||||||
| AVERAGE | 6c | AVERAGE | OUT OF TOLERANCE | ||||||||||||
| Results By: | Date: | Results By: | Date: | Remarks | |||||||||||
| 7 | |||||||||||||||
| VOLUME TEST | |||||||||||||||
| Scale Used in Test / Brand / Model / Serial No. | Kettle Brand & Serial No. | Results By: / Date of Test: | |||||||||||||
| 8a | 8b | 8c | |||||||||||||
| GROSS - TARE = NET WEIGHT (1,098.08 g at 68 °F) | 8d | OR Filled kettle ± 1.0 g of Standard counter weight. | |||||||||||||
| Form FGIS-927 (03/25) Previous editions are obsolete. Expires 03/28 | |||||||||||||||
|
|||||||||||
| File Type | application/vnd.openxmlformats-officedocument.spreadsheetml.sheet |
| File Modified | 0000-00-00 |
| File Created | 0000-00-00 |