ONE-TIME implementation burden (averaged over first 3 yrs.) of RM12-3 (System Refresh) Final Rule

FERC-920 (removal of eTag ID burden due to RM10-12 Clarifying Order, issued 6/16/2016), Electric Quarterly Report (EQR)

ErrataDataDictionary20121119-3018

ONE-TIME implementation burden (averaged over first 3 yrs.) of RM12-3 (System Refresh) Final Rule

OMB: 1902-0255

Document [doc]
Download: doc | pdf


UNITED STATES OF AMERICA

FEDERAL ENERGY REGULATORY COMMISSION



Revisions to Electric Quarterly Report Filing Process


Docket No. RM12-3-000






ERRATA NOTICE


(November 19, 2012)


On November 15, 2012, the Commission issued a Final Rule in the above-captioned proceeding, Revisions to Electric Quarterly Report Filing Process, 141 FERC ¶ 61,120 (2012) (Final Rule). In the Final Rule, Appendix B included typographical errors that created numbering errors in the old and new field boxes and included fields that should have been deleted. This errata notice and the attached replacement Appendix B, the EQR Data Dictionary, correct the originally issued Appendix B.





Kimberly D. Bose,

Secretary.








Appendix B: EQR Data Dictionary


Electric Quarterly Report Data Dictionary

Version 2.1 (issued November 15, 2012)1

EQR Data Dictionary

ID Data

Field #

Field

Required

Value

Definition

Old

New

1

1

Filer Unique Identifier

FS# (where “#” is an integer)

(Seller) – An identifier (e.g., “FS1”, “FS2”) used to designate a record containing Seller identification information in a comma-delimited (csv) file that is imported into the EQR filing. One record for each seller company may be imported into an EQR for a given quarter.

1

1

Filer Unique Identifier

FA1

(Agent) – An identifier (i.e., “FA1”) used to designate a record containing Agent identification information in a comma-delimited (csv) file that is imported into the EQR filing. Only one record with the FA1 identifier may be imported into an EQR for a given quarter.

2

2

Company Name

Unrestricted text (100 characters)

(Seller) – The name of the company that is authorized to make sales as indicated in the company's FERC tariff(s).

2

2

Company Name

Unrestricted text (100 characters)

(Agent) – The name of the entity completing the EQR filing. The Agent's Company Name need not be the name of the company under Commission jurisdiction.

3

X






3

Company Identifier

A 7-digit integer proceeded by the letter “C”

(Seller) – Identifier obtained through the Commission’s Company Registration system.

3

4

Contact Name

Unrestricted text (50 characters)

(Seller) – The name of the contact for the company authorized to make sales as indicated in the company's FERC tariff(s).

3

4

Contact Name

Unrestricted text (50 characters)

(Agent) – Name of the contact for the Agent, usually the person who prepares the filing.

4

5

Contact Title

Unrestricted text (50 characters)

Title of contact identified in Field Number 4.

5

6

Contact Address

Unrestricted text

Street address for contact identified in Field Number 4.

6

7

Contact City

Unrestricted text (30 characters)

City for the contact identified in Field Number 4.

7

8

Contact State

Unrestricted text (2 characters)

Two character state or province abbreviations for the contact identified in Field Number 4.

8

9

Contact Zip

Unrestricted text (10 characters)

Zip code for the contact identified in Field Number 4.

9

10

Contact Country Name

CA - Canada

MX - Mexico

US – United States

UK – United Kingdom

Country (USA, Canada, Mexico, or United Kingdom) for contact address identified in Field Number 4.

10

11

Contact Phone

Unrestricted text (20 characters)

Phone number of contact identified in Field Number 4.

11

12

Contact E-Mail

Unrestricted text

E-mail address of contact identified in Field Number 4.

12

13

Transactions Reported to Index Price Publisher(s)

Y (Yes)
N (No)


Filers should indicate whether they have reported their sales transactions to index price publisher(s). If they have, filers should indicate specifically which index publisher(s) in Field Number 73.

13

14

Filing Quarter

YYYYMM

A six digit reference number used by the EQR software to indicate the quarter and year of the filing for the purpose of importing data from csv files. The first 4 numbers represent the year (e.g., 2007). The last 2 numbers represent the last month of the quarter (e.g., 03=1st quarter; 06=2nd quarter, 09=3rd quarter, 12= 4th quarter).



EQR Data Dictionary

Contract Data

Field #

Field

Required

Value

Definition

Old

New

14

15

Contract Unique ID

An integer proceeded by the letter “C” (only used when importing contract data)

An identifier beginning with the letter “C” and followed by a number (e.g., “C1”, “C2”) used to designate a record containing contract information in a comma-delimited (csv) file that is imported into the EQR filing. One record for each contract product may be imported into an EQR for a given quarter.

15

16

Seller Company Name

Unrestricted text (100 characters)

The name of the company that is authorized to make sales as indicated in the company’s FERC tariff(s). This name must match the name provided as a Seller's “Company Name” in Field Number 2 of the ID Data (Seller Data).

16

17

Customer Company Name

Unrestricted text (70 characters)

The name of the counterparty.

17

X





17

18

Contract Affiliate

Y (Yes)

N (No)

The customer is an affiliate if it controls, is controlled by or is under common control with the seller. This includes a division that operates as a functional unit. A customer of a seller who is an Exempt Wholesale Generator may be defined as an affiliate under the Public Utility Holding Company Act and the FPA.

18

19

FERC Tariff Reference

Unrestricted text (60 characters)

The FERC tariff reference cites the document that specifies the terms and conditions under which a Seller is authorized to make transmission sales, power sales or sales of related jurisdictional services at cost-based rates or at market-based rates. If the sales are market-based, the tariff that is specified in the FERC order granting the Seller Market Based Rate Authority must be listed.

19

20

Contract Service Agreement ID

Unrestricted text (30 characters)

Unique identifier given to each service agreement that can be used by the filing company to produce the agreement, if requested. The identifier may be the number assigned by FERC for those service agreements that have been filed with and accepted by the Commission, or it may be generated as part of an internal identification system.

20

21

Contract Execution Date

YYYYMMDD

The date the contract was signed. If the parties signed on different dates, use the most recent date signed.

21

22

Commencement Date of Contract Terms

YYYYMMDD

The date the terms of the contract reported in fields 18, 23 and 25 through 44 (as defined in the data dictionary) became effective. If those terms became effective on multiple dates (i.e.: due to one or more amendments), the date to be reported in this field is the date the most recent amendment became effective. If the contract or the most recent reported amendment does not have an effective date, the date when service began pursuant to the contract or most recent reported amendment may be used. If the terms reported in fields 18, 23 and 25 through 44 have not been amended since January 1, 2009, the initial date the contract became effective (or absent an effective date the initial date when service began) may be used.

22

23

Contract Termination Date

If specified in the contract.

YYYYMMDD

The date that the contract expires.

23

24

Actual Termination Date

If contract terminated.

YYYYMMDD

The date the contract actually terminates.

24

25

Extension Provision Description

Unrestricted text

Description of terms that provide for the continuation of the contract.

25

26

Class Name

---

See definitions of each class name below.

25

26

Class Name

F - Firm

For transmission sales, a service or product that always has priority over non-firm service. For power sales, a service or product that is not interruptible for economic reasons.

25

26

Class Name

NF - Non-firm

For transmission sales, a service that is reserved and/or scheduled on an as-available basis and is subject to curtailment or interruption at a lesser priority compared to Firm service. For an energy sale, a service or product for which delivery or receipt of the energy may be interrupted for any reason or no reason, without liability on the part of either the buyer or seller.

25

26

Class Name

UP - Unit Power Sale

Designates a dedicated sale of energy and capacity from one or more than one specified generation unit(s).

25

26

Class Name

N/A - Not Applicable

To be used only when the other available Class Names do not apply.

26

27

Term Name

LT - Long Term

ST - Short Term

N/A - Not Applicable

Contracts with durations of one year or greater are long-term. Contracts with shorter durations are short-term.

27

28

Increment Name

---

See definitions for each increment below.

27

28

Increment Name

H - Hourly

Terms of the contract (if specifically noted in the contract) set for up to 6 consecutive hours (≤ 6 consecutive hours).

27

28

Increment Name

D - Daily

Terms of the contract (if specifically noted in the contract) set for more than 6 and up to 60 consecutive hours (>6 and ≤ 60 consecutive hours).

27

28

Increment Name

W - Weekly

Terms of the contract (if specifically noted in the contract) set for over 60 consecutive hours and up to 168 consecutive hours (>60 and ≤ 168 consecutive hours).

27

28

Increment Name

M - Monthly

Terms of the contract (if specifically noted in the contract) set for more than 168 consecutive hours up to, but not including, one year (>168 consecutive hours and < 1 year).

27

28

Increment Name

Y - Yearly

Terms of the contract (if specifically noted in the contract) set for one year or more (≥ 1 year).

27

28

Increment Name

N/A - Not Applicable

Terms of the contract do not specify an increment.

28

29

Increment Peaking Name

---

See definitions for each increment peaking name below.

28

29

Increment Peaking Name

FP - Full Period

The product described may be sold during those hours designated as on-peak and off-peak in the NERC region of the point of delivery.

28

29

Increment Peaking Name

OP - Off-Peak

The product described may be sold only during those hours designated as off-peak in the NERC region of the point of delivery.

28

29

Increment Peaking Name

P - Peak

The product described may be sold only during those hours designated as on-peak in the NERC region of the point of delivery.

28

29

Increment Peaking Name

N/A - Not Applicable

To be used only when the increment peaking name is not specified in the contract.

29

30

Product Type Name

---

See definitions for each product type below.

29

30

Product Type Name

CB - Cost Based

Energy or capacity sold under a FERC-approved cost-based rate tariff.

29

30

Product Type Name

CR - Capacity Reassignment

An agreement under which a transmission provider sells, assigns or transfers all or portion of its rights to an eligible customer.

29

30

Product Type Name

MB - Market Based

Energy or capacity sold under the seller’s FERC-approved market-based rate tariff.

29

30

Product Type Name

T - Transmission

The product is sold under a FERC-approved transmission tariff.

29

30

Product Type Name

Other

The product cannot be characterized by the other product type names.

30

31

Product Name

See Product Name Table, Appendix A.

Description of product being offered.

31

32

Quantity

If specified in the contract

Number with up to 4 decimals

Quantity for the contract product identified.

32

33

Units

If specified in the contract

See Units Table, Appendix E.

Measure stated in the contract for the product sold.

33

34

Rate

One of four rate fields (34, 35, 36, or 37) must be included.

Number with up to 4 decimals

The charge for the product per unit as stated in the contract.

34

35

Rate Minimum

One of four rate fields (34, 35, 36, or 37) must be included

Number with up to 4 decimals

Minimum rate to be charged per the contract, if a range is specified.

35

36

Rate Maximum

One of four rate fields (34, 35, 36, or 37) must be included

Number with up to 4 decimals

Maximum rate to be charged per the contract, if a range is specified.

36

37

Rate Description

One of four rate fields (34, 35, 36, or 37) must be included

Unrestricted text

Text description of rate. If the rate is currently available on the FERC website, a citation of the FERC Accession Number and the relevant FERC tariff including page number or section may be included instead of providing the entire rate algorithm. If the rate is not available on the FERC website, include the rate algorithm, if rate is calculated. If the algorithm would exceed the 150 character field limit, it may be provided in a descriptive summary (including bases and methods of calculations) with a detailed citation of the relevant FERC tariff including page number and section. If more than 150 characters are required, the contract product may be repeated in a subsequent line of data until the rate is adequately described.

37

38

Rate Units

If specified in the contract

See Rate Units Table, Appendix F.

Measure stated in the contract for the product sold.

38

39

Point of Receipt Balancing Authority(PORBA)

If specified in the contract

See Balancing Authority Table, Appendix B.

The registered NERC Balancing Authority (formerly called NERC Control Area) where service begins for a transmission or transmission-related jurisdictional sale. The Balancing Authority will be identified with the abbreviation used in OASIS applications. If receipt occurs at a trading hub specified in the EQR software, the term “Hub” should be used.

39

40

Point of Receipt Specific Location (PORSL)

If specified in the contract

Unrestricted text (50 characters). If “HUB” is selected for PORCA, see Hub Table, Appendix C.

The specific location at which the product is received if designated in the contract. If receipt occurs at a trading hub, a standardized hub name must be used. If more points of receipt are listed in the contract than can fit into the 50 character space, a description of the collection of points may be used. ‘Various,’ alone, is unacceptable unless the contract itself uses that terminology.

40

41

Point of Delivery Balancing Authority(PODBA)

If specified in the contract

See Balancing Authority Table, Appendix B.

The registered NERC Balancing Authority (formerly called NERC Control Area) where a jurisdictional product is delivered and/or service ends for a transmission or transmission-related jurisdictional sale. The Balancing Authority will be identified with the abbreviation used in OASIS applications. If delivery occurs at the interconnection of two control areas, the control area that the product is entering should be used. If delivery occurs at a trading hub specified in the EQR software, the term “Hub” should be used.

41

42

Point of Delivery Specific Location (PODSL)

If specified in the contract

Unrestricted text (50 characters). If “HUB” is selected for PODCA, see Hub Table, Appendix C.

The specific location at which the product is delivered if designated in the contract. If receipt occurs at a trading hub, a standardized hub name must be used.

42

43

Begin Date

If specified in the contract

YYYYMMDDHHMM

First date for the sale of the product at the rate specified.

43

44

End Date

If specified in the contract

YYYYMMDDHHMM

Last date for the sale of the product at the rate specified.

45

X






EQR Data Dictionary

Transaction Data

Field #

Field

Required

Value

Definition

Old

New

44

45

Transaction Unique ID

An integer proceeded by the letter “T” (only used when importing transaction data)

An identifier beginning with the letter “T” and followed by a number (e.g., “T1”, “T2”) used to designate a record containing transaction information in a comma-delimited (csv) file that is imported into the EQR filing. One record for each transaction record may be imported into an EQR for a given quarter. A new transaction record must be used every time a price changes in a sale.

45

46

Seller Company Name

Unrestricted text (100 Characters)

The name of the company that is authorized to make sales as indicated in the company's FERC tariff(s). This name must match the name provided as a Seller's “Company Name” in Field 2 of the ID Data (Seller Data).

46

47

Customer Company Name

Unrestricted text (70 Characters)

The name of the counterparty.

49

X





47

48

FERC Tariff Reference

Unrestricted text (60 Characters)

The FERC tariff reference cites the document that specifies the terms and conditions under which a Seller is authorized to make transmission sales, power sales or sales of related jurisdictional services at cost-based rates or at market-based rates. If the sales are market-based, the tariff that is specified in the FERC order granting the Seller Market Based Rate Authority must be listed.

48

49

Contract Service Agreement ID

Unrestricted text (30 Characters)

Unique identifier given to each service agreement that can be used by the filing company to produce the agreement, if requested. The identifier may be the number assigned by FERC for those service agreements that have been filed and approved by the Commission, or it may be generated as part of an internal identification system.

49

50

Transaction Unique Identifier

Unrestricted text (24 Characters)

Unique reference number assigned by the seller for each transaction.

50

51

Transaction Begin Date

YYYYMMDDHHMM (csv import)

MMDDYYYYHHMM (manual entry)

First date and time the product is sold during the quarter.

51

52

Transaction End Date

YYYYMMDDHHMM (csv import)

MMDDYYYYHHMM (manual entry)

Last date and time the product is sold during the quarter.

52

53

Trade Date

YYYYMMDD (csv import)
MMDDYYYY (manual entry)

The date upon which the parties made the legally binding agreement on the price of a transaction.

53

54

Exchange/Brokerage Service


See Exchange/Brokerage Service Table, Appendix H.

If a broker service is used to consummate or effectuate a transaction, the term “Broker” shall be selected from the Commission-provided list. If an exchange is used, the specific exchange that is used shall be selected from the Commission-provided list.

54

55

Type of Rate

---

See type of rate definitions below.

54

55

Type of Rate

Fixed

A fixed charge per unit of consumption.

54

55

Type of Rate

Formula

A calculation of a rate based upon a formula that does not contain an index component.

54

55

Type of Rate

Electric Index

A calculation of a rate based upon an index or a formula that contains an index component.

54

55

Type of Rate

RTO/ISO

A rate that is based on an RTO/ISO published price or formula that contains an RTO/ISO price component.

55

56

Time Zone

See Time Zone Table, Appendix D.

The time zone in which the sales will be made under the contract.

56

57

Point of Delivery Balancing Authority (PODBA)

See Balancing Authority Table, Appendix B.

The registered NERC Balancing Authority (formerly called NERC Control Area) abbreviation used in OASIS applications.

57

58

Point of Delivery Specific Location (PODSL)

Unrestricted text (50 characters). If “HUB” is selected for PODBA, see Hub Table, Appendix C.

The specific location at which the product is delivered. If receipt occurs at a trading hub, a standardized hub name must be used.

58

59

Class Name

---

See class name definitions below.

58

59

Class Name

F - Firm

A sale, service or product that is not interruptible for economic reasons.

58

59

Class Name

NF - Non-firm

A sale for which delivery or receipt of the energy may be interrupted for any reason or no reason, without liability on the part of either the buyer or seller.

58

59

Class Name

UP - Unit Power Sale

Designates a dedicated sale of energy and capacity from one or more than one specified generation unit(s).

58

59

Class Name

BA - Billing Adjustment

Designates an incremental material change to one or more transactions due to a change in settlement results. “BA” may be used in a refiling after the next quarter’s filing is due to reflect the receipt of new information. It may not be used to correct an inaccurate filing.

58

59

Class Name

N/A - Not Applicable

To be used only when the other available class names do not apply.

59

60

Term Name

LT - Long Term

ST - Short TermN/A - Not Applicable

Power sales transactions with durations of one year or greater are long-term. Transactions with shorter durations are short-term.

60

61

Increment Name

---

See increment name definitions below.

60

61

Increment Name

H - Hourly

Terms of the particular sale set for up to 6 consecutive hours (≤ 6 consecutive hours) Includes LMP based sales in ISO/RTO markets.

60

61

Increment Name

D - Daily

Terms of the particular sale set for more than 6 and up to 60 consecutive hours (>6 and ≤ 60 consecutive hours). Includes sales over a peak or off-peak block during a single day.

60

61

Increment Name

W - Weekly

Terms of the particular sale set for over 60 consecutive hours and up to 168 consecutive hours (>60 and ≤ 168 consecutive hours). Includes sales for a full week and sales for peak and off-peak blocks over a particular week.

60

61

Increment Name

M - Monthly

Terms of the particular sale set for set for more than 168 consecutive hours up to, but not including, one year (>168 consecutive hours and < 1 year). Includes sales for full month or multi-week sales during a given month.

60

61

Increment Name

Y - Yearly

Terms of the particular sale set for one year or more (≥ 1 year). Includes all long-term contracts with defined pricing terms (fixed-price, formula, or index).

60

61

Increment Name

N/A - Not Applicable

To be used only when other available increment names do not apply.

61

62

Increment Peaking Name

---

See definitions for increment peaking below.

61

62

Increment Peaking Name

FP - Full Period

The product described was sold during Peak and Off-Peak hours.

61

62

Increment Peaking Name

OP - Off-Peak

The product described was sold only during those hours designated as off-peak in the NERC region of the point of delivery.

61

62

Increment Peaking Name

P - Peak

The product described was sold only during those hours designated as on-peak in the NERC region of the point of delivery.

61

62

Increment Peaking Name

N/A - Not Applicable

To be used only when the other available increment peaking names do not apply.

62

63

Product Name

See Product Names Table, Appendix A.

Description of product being offered.

63

64

Transaction Quantity

Number with up to 4 decimals.

The quantity of the product in this transaction.

64

65

Price

Number with up to 6 decimals.

Actual price charged for the product per unit. The price reported cannot be averaged or otherwise aggregated

65

66

Rate Units

See Rate Units Table, Appendix F

Measure appropriate to the price of the product sold.

66

67

Standardized Quantity

Number with up to 4 decimals.

For product names energy, capacity, and booked out power only. Specify the quantity in MWh if the product is energy or booked out power and specify the quantity in MW if the product is capacity.

67

68

Standardized Price

Number with up to 6 decimals.

For product names energy, capacity, and booked out power only. Specify the price in $/MWh if the product is energy or booked out power and specify the price in $/MW-month if the product is capacity.

68

69

Total Transmission Charge

Number with up to 2 decimals

Payments received for transmission services when explicitly identified.

69

70

Total Transaction Charge

Number with up to 2 decimals

Transaction Quantity (Field 64) times Price (Field 65) plus Total Transmission Charge (Field 69).



EQR Data Dictionary

Index Reporting Data

Field #

Field

Required

Value

Definition

Old

New

70

71

Filer Unique Identifier

FS# (where “#” is an integer)

The “FS” seller number from the ID Data table corresponding to the index reporting company.

71

72

Seller Company Name

Unrestricted text (100 characters)

The name of the company that is authorized to make sales as indicated in the company’s FERC tariff(s). This name must match the name provided as a Seller's “Company Name” in Field Number 2 of the ID Data (Seller Data).

72

73

Index Price Publisher(s) To Which Sales Transactions Have Been Reported

If "Yes" is selected for Field 13, see Index Price Publisher, Appendix G.

The index price publisher(s) to which sales transactions have been reported.

73

74

Transactions Reported

Unrestricted text (100 characters)

Description of the types of transactions reported to the index publisher identified in this record.


EQR Data Dictionary

e-Tag Data

Field #

Field

Required

Value

Definition

Old

New

74

75

e-Tag ID

If an e-Tag ID was used to schedule the EQR transaction

Unrestricted text (30 Characters)

The e-Tag ID contains: The Source Balancing Authority where the generation is located; The Purchasing-Selling Balancing Authority Entity Code; the e-Tag Code; and the Sink Balancing Authority.

75

76

e-Tag Begin Date

If an e-Tag ID was used to schedule the EQR transaction

YYYYMMDD (csv import)
MMDDYYYY (manual entry)

The first date the transaction is scheduled using the e-Tag ID reported in Field Number 75. Begin Date must not be before the Transaction Begin Date specified in Field Number 51 and must be reported in the same time zone specified in Field Number 56.

76

77

e-Tag End Date

If an e-Tag ID was used to schedule the EQR transaction

YYYYMMDD (csv import)
MMDDYYYY (manual entry)

The last date the transaction is scheduled using the e-Tag ID reported in Field Number 75. End Date must not be after the Transaction End Date specified in Field Number 52 and must be reported in the same time zone specified in Field Number 56.

77

78

Transaction Unique Identifier

If an e-Tag ID was used to schedule the EQR transaction

Unrestricted text (24 Characters)

Unique reference number assigned by the seller for each transaction that must be the same as reported in Field Number 50.



EQR Data Dictionary

Appendix A. Product Names

Product Name

Contract Product

Transaction Product

Definition

BLACK START SERVICE

Service available after a system -wide blackout where a generator participates in system restoration activities without the availability of an outside electric supply (Ancillary Service).

BOOKED OUT POWER


Energy or capacity contractually committed bilaterally for delivery but not actually delivered due to some offsetting or countervailing trade (Transaction only).

CAPACITY

A quantity of demand that is charged on a $/KW or $/MW basis.

CUSTOMER CHARGE

Fixed contractual charges assessed on a per customer basis that could include billing service.

DIRECT ASSIGNMENT FACILITIES CHARGE


Charges for facilities or portions of facilities that are constructed or used for the sole use/benefit of a particular customer.

EMERGENCY ENERGY


Contractual provisions to supply energy or capacity to another entity during critical situations.

ENERGY

A quantity of electricity that is sold or transmitted over a period of time.

ENERGY IMBALANCE

Service provided when a difference occurs between the scheduled and the actual delivery of energy to a load obligation (Ancillary Service). For Contracts,

reported if the contract provides for sale of the product. For Transactions, sales

by third-party providers (i.e., non-transmission function) are reported.

EXCHANGE

Transaction whereby the receiver accepts delivery of energy for a supplier's account and returns energy at times, rates, and in amounts as mutually agreed if the receiver is not an RTO/ISO.

FUEL CHARGE

Charge based on the cost or amount of fuel used for generation.

GENERATOR IMBALANCE

Service provided when a difference occurs between the output of a generator

located in the Transmission Provider’s Control Area and a delivery schedule from

that generator to (1) another Control Area or (2) a load within the Transmission

Provider’s Control Area over a single hour (Ancillary Service). For Contracts, reported if the contract provides for sale of the product. For Transactions, sales by third-party providers (i.e., non-transmission function) are reported.

GRANDFATHERED BUNDLED

Services provided for bundled transmission, ancillary services and energy under contracts effective prior to Order No. 888's OATTs.

INTERCONNECTION AGREEMENT


Contract that provides the terms and conditions for a generator, distribution system owner, transmission owner, transmission provider, or transmission system to physically connect to a transmission system or distribution system.

MEMBERSHIP AGREEMENT


Agreement to participate and be subject to rules of a system operator.

MUST RUN AGREEMENT


An agreement that requires a unit to run.

NEGOTIATED-RATE TRANSMISSION

Transmission performed under a negotiated rate contract (applies only to merchant transmission companies).

NETWORK


Transmission service under contract providing network service.

NETWORK OPERATING AGREEMENT


An executed agreement that contains the terms and conditions under which a network customer operates its facilities and the technical and operational matters associated with the implementation of network integration transmission service.

OTHER

Product name not otherwise included.

POINT-TO-POINT AGREEMENT


Transmission service under contract between specified Points of Receipt and Delivery.

REACTIVE SUPPLY & VOLTAGE CONTROL

Production or absorption of reactive power to maintain voltage levels on transmission systems (Ancillary Service).

REAL POWER TRANSMISSION LOSS

The loss of energy, resulting from transporting power over a transmission system.

REASSIGNMENT AGREEMENT


Transmission capacity reassignment agreement.

REGULATION & FREQUENCY RESPONSE

Service providing for continuous balancing of resources (generation and interchange) with load, and for maintaining scheduled interconnection frequency by committing on-line generation where output is raised or lowered and by other non-generation resources capable of providing this service as necessary to follow the moment-by-moment changes in load (Ancillary Service). For Contracts, reported if the contract provides for sale of the product. For Transactions, sales by third-party providers (i.e., non-transmission function) are reported.

REQUIREMENTS SERVICE

Firm, load-following power supply necessary to serve a specified share of customer's aggregate load during the term of the agreement. Requirements service may include some or all of the energy, capacity and ancillary service products. (If the components of the requirements service are priced separately, they should be reported separately in the transactions tab.)

SCHEDULE SYSTEM CONTROL & DISPATCH

Scheduling, confirming and implementing an interchange schedule with other Balancing Authorities, including intermediary Balancing Authorities providing transmission service, and ensuring operational security during the interchange transaction (Ancillary Service).

SPINNING RESERVE

Unloaded synchronized generating capacity that is immediately responsive to system frequency and that is capable of being loaded in a short time period or non-generation resources capable of providing this service (Ancillary Service). For Contracts, reported if the contract provides for sale of the product. For Transactions, sales by third-party providers (i.e., non-transmission function) are reported.

SUPPLEMENTAL RESERVE

Service needed to serve load in the event of a system contingency, available with greater delay than SPINNING RESERVE. This service may be provided by generating units that are on-line but unloaded, by quick-start generation, or by interruptible load or other non-generation resources capable of providing this service (Ancillary Service). For Contracts, reported if the contract provides for sale of the product. For Transactions, sales by third-party providers (i.e., non-transmission function) are reported.

SYSTEM OPERATING AGREEMENTS


An executed agreement that contains the terms and conditions under which a system or network customer shall operate its facilities and the technical and operational matters associated with the implementation of network.

TOLLING ENERGY

Energy sold from a plant whereby the buyer provides fuel to a generator (seller) and receives power in return for pre-established fees.

TRANSMISSION OWNERS AGREEMENT


The agreement that establishes the terms and conditions under which a transmission owner transfers operational control over designated transmission facilities.

UPLIFT

A make-whole payment by an RTO/ISO to a utility.



EQR Data Dictionary

Appendix B. Balancing Authority

Balancing Authority

Abbreviation

Outside US*

AESC, LLC - Wheatland CIN

AEWC


Alabama Electric Cooperative, Inc.

AEC


Alberta Electric System Operator

AESO

Alliant Energy Corporate Services, LLC - East

ALTE


Alliant Energy Corporate Services, LLC- West

ALTW


Ameren Transmission. Illinois

AMIL


Ameren Transmission. Missouri

AMMO


American Transmission Systems, Inc.

FE


Aquila Networks – Kansas

WPEK


Aquila Networks - Missouri Public Service

MPS


Aquila Networks - West Plains Dispatch

WPEC


Arizona Public Service Company

AZPS


Associated Electric Cooperative, Inc.

AECI


Avista Corp.

AVA


Batesville Balancing Authority

BBA


BC Hydro T & D - Grid Operations

BCHA

Big Rivers Electric Corp.

BREC


Board of Public Utilities

KACY


Bonneville Power Administration Transmission

BPAT


British Columbia Transmission Corporation

BCTC

California Independent System Operator

CISO


Carolina Power & Light Company - CPLW

CPLW


Carolina Power and Light Company - East

CPLE


Central and Southwest

CSWS


Chelan County PUD

CHPD


Cinergy Corporation

CIN


City of Homestead

HST


City of Independence P&L Dept.

INDN


City of Tallahassee

TAL


City Water Light & Power

CWLP


City Utilities of Springfield

SPRM


Cleco Power LLC

CLEC


Columbia Water & Light

CWLD


Comision Federal de Electricidad

CFE

Comision Federal de Electricidad

CFEN

Constellation Energy Control and Dispatch

GRIF


Constellation Energy Control and Dispatch - Arkansas

PUPP


Constellation Energy Control and Dispatch - City of Benton, AR

BUBA


Constellation Energy Control and Dispatch - City of Ruston, LA

DERS


Constellation Energy Control and Dispatch - Conway, Arkansas

CNWY


Constellation Energy Control and Dispatch - Gila River

GRMA


Constellation Energy Control and Dispatch - Glacier Wind Energy

GWA


Constellation Energy Control and Dispatch - Harquehala

HGMA


Constellation Energy Control and Dispatch - North Little Rock, AK

DENL


Constellation Energy Control and Dispatch - Osceola Municipal Light

OMLP


Constellation Energy Control and Dispatch - Plum Point

PLUM


Constellation Energy Control and Dispatch – Red Mesa

REDM


Constellation Energy Control and Dispatch - West Memphis, Arkansas

WMUC


Dairyland Power Cooperative

DPC


DECA, LLC - Arlington Valley

DEAA


Duke Energy Corporation

DUK


East Kentucky Power Cooperative, Inc.

EKPC


El Paso Electric

EPE


Electric Energy, Inc.

EEI


Empire District Electric Co., The

EDE


Entergy

EES


ERCOT ISO

ERCO


Florida Municipal Power Pool

FMPP


Florida Power & Light

FPL


Florida Power Corporation

FPC


Gainesville Regional Utilities

GVL


Grand River Dam Authority

GRDA


Grant County PUD No.2

GCPD


Great River Energy

GRE


Great River Energy

GREC


Great River Energy

GREN


Great River Energy

GRES


GridAmerica

GA


Hoosier Energy

HE


Hydro-Quebec, TransEnergie

HQT

Idaho Power Company

IPCO


Imperial Irrigation District

IID


Indianapolis Power & Light Company

IPL


ISO New England Inc.

ISNE


JEA

JEA


Kansas City Power & Light, Co

KCPL


Lafayette Utilities System

LAFA


LG&E Energy Transmission Services

LGEE


Lincoln Electric System

LES


Los Angeles Department of Water and Power

LDWP


Louisiana Energy & Power Authority

LEPA


Louisiana Generating, LLC

LAGN


Louisiana Generating, LLC - City of Conway

CWAY


Louisiana Generating, LLC - City of West Memphis

WMU


Louisiana Generating, LLC - North Little Rock

NLR


Madison Gas and Electric Company

MGE


Manitoba Hydro Electric Board, Transmission Services

MHEB

Michigan Electric Coordinated System

MECS


Michigan Electric Coordinated System - CONS

CONS


Michigan Electric Coordinated System - DECO

DECO


MidAmerican Energy Company

MEC


Midwest ISO

MISO


Minnesota Power, Inc.

MP


Montana-Dakota Utilities Co.

MDU


Muscatine Power and Water

MPW


Nebraska Public Power District

NPPD


Nevada Power Company

NEVP


New Brunswick System Operator

NBSO

New Horizons Electric Cooperative

NHC1


New York Independent System Operator

NYIS


Northern Indiana Public Service Company

NIPS


Northern States Power Company

NSP


NorthWestern Energy

NWMT


Ohio Valley Electric Corporation

OVEC


Oklahoma Gas and Electric

OKGE


Ontario - Independent Electricity System Operator

ONT

OPPD CA/TP

OPPD


Otter Tail Power Company

OTP


P.U.D. No. 1 of Douglas County

DOPD


PacifiCorp-East

PACE


PacifiCorp-West

PACW


PJM Interconnection

PJM


Portland General Electric

PGE


Public Service Company of Colorado

PSCO


Public Service Company of New Mexico

PNM


Puget Sound Energy Transmission

PSEI


Reedy Creek Improvement District

RC


Sacramento Municipal Utility District

SMUD


Salt River Project

SRP


Santee Cooper

SC


SaskPower Grid Control Centre

SPC

Seattle City Light

SCL


Seminole Electric Cooperative

SEC


Sierra Pacific Power Co. - Transmission

SPPC


South Carolina Electric & Gas Company

SCEG


South Mississippi Electric Power Association

SME


South Mississippi Electric Power Association

SMEE


Southeastern Power Administration - Hartwell

SEHA


Southeastern Power Administration - Russell

SERU


Southeastern Power Administration - Thurmond

SETH


Southern Company Services, Inc.

SOCO


Southern Illinois Power Cooperative

SIPC


Southern Indiana Gas & Electric Co.

SIGE


Southern Minnesota Municipal Power Agency

SMP


Southwest Power Pool

SWPP


Southwestern Power Administration

SPA


Southwestern Public Service Company

SPS


Sunflower Electric Power Corporation

SECI


Tacoma Power

TPWR


Tampa Electric Company

TEC


Tennessee Valley Authority ESO

TVA


Trading Hub

HUB


TRANSLink Management Company

TLKN


Tucson Electric Power Company

TEPC


Turlock Irrigation District

TIDC


Upper Peninsula Power Co.

UPPC


Utilities Commission, City of New Smyrna Beach

NSB


Westar Energy - MoPEP Cities

MOWR


Western Area Power Administration - Colorado-Missouri

WACM


Western Area Power Administration - Lower Colorado

WALC


Western Area Power Administration - Upper Great Plains East

WAUE


Western Area Power Administration - Upper Great Plains West

WAUW


Western Farmers Electric Cooperative

WFEC


Western Resources dba Westar Energy

WR


Wisconsin Energy Corporation

WEC


Wisconsin Public Service Corporation

WPS


Yadkin, Inc.

YAD


* Balancing authorities outside the United States may only be used in the Contract Data section to identify specified receipt/delivery points in jurisdictional transmission contracts.


EQR Data Dictionary

Appendix C. Hub


HUB

Definition

ADHUB

The aggregated Locational Marginal Price (“LMP”) nodes defined by PJM Interconnection, LLC as the AEP/Dayton Hub.

AEPGenHub

The aggregated Locational Marginal Price (“LMP”) nodes defined by PJM Interconnection, LLC as the AEPGenHub.

COB

The set of delivery points along the California-Oregon commonly identified as and agreed to by the counterparties to constitute the COB Hub.

Cinergy (into)

The set of delivery points commonly identified as and agreed to by the counterparties to constitute delivery into the Cinergy balancing authority.

Cinergy Hub (MISO)

The aggregated Elemental Pricing nodes ("Epnodes") defined by the Midwest Independent Transmission System Operator, Inc., as Cinergy Hub (MISO).

Entergy (into)

The set of delivery points commonly identified as and agreed to by the counterparties to constitute delivery into the Entergy balancing authority.

FE Hub

The aggregated Elemental Pricing nodes ("Epnodes") defined by the Midwest Independent Transmission System Operator, Inc., as FE Hub (MISO).

Four Corners

The set of delivery points at the Four Corners power plant commonly identified as and agreed to by the counterparties to constitute the Four Corners Hub.

Illinois Hub (MISO)

The aggregated Elemental Pricing nodes ("Epnodes") defined by the Midwest Independent Transmission System Operator, Inc., as Illinois Hub (MISO).

Mead

The set of delivery points at or near Hoover Dam commonly identified as and agreed to by the counterparties to constitute the Mead Hub.

Michigan Hub (MISO)

The aggregated Elemental Pricing nodes ("Epnodes") defined by the Midwest Independent Transmission System Operator, Inc., as Michigan Hub (MISO).

Mid-Columbia (Mid-C)

The set of delivery points along the Columbia River commonly identified as and agreed to by the counterparties to constitute the Mid-Columbia Hub.

Minnesota Hub (MISO)

The aggregated Elemental Pricing nodes ("Epnodes") defined by the Midwest Independent Transmission System Operator, Inc., as Minnesota Hub (MISO).

NEPOOL (Mass Hub)

The aggregated Locational Marginal Price (“LMP”) nodes defined by ISO New England Inc., as Mass Hub.

NIHUB

The aggregated Locational Marginal Price (“LMP”) nodes defined by PJM Interconnection, LLC as the Northern Illinois Hub.

NOB

The set of delivery points along the Nevada-Oregon border commonly identified as and agreed to by the counterparties to constitute the NOB Hub. 

NP15

The set of delivery points north of Path 15 on the California transmission grid commonly identified as and agreed to by the counterparties to constitute the NP15 Hub.

NWMT

The set of delivery points commonly identified as and agreed to by the counterparties to constitute delivery into the Northwestern Energy Montana balancing authority.

PJM East Hub

The aggregated Locational Marginal Price nodes (“LMP”) defined by PJM Interconnection, LLC as the PJM East Hub. 

PJM South Hub

The aggregated Locational Marginal Price (“LMP”) nodes defined by PJM Interconnection, LLC as the PJM South Hub.

PJM West Hub

The aggregated Locational Marginal Price (“LMP”) nodes defined by PJM Interconnection, LLC as the PJM Western Hub.

Palo Verde

The switch yard at the Palo Verde nuclear power station west of Phoenix in Arizona.  Palo Verde Hub includes the Hassayampa switchyard 2 miles south of Palo Verde.

SOCO (into)

The set of delivery points commonly identified as and agreed to by the counterparties to constitute delivery into the Southern Company balancing authority.

SP15

The set of delivery points south of Path 15 on the California transmission grid commonly identified as and agreed to by the counterparties to constitute the SP15 Hub.

TVA (into)

The set of delivery points commonly identified as and agreed to by the counterparties to constitute delivery into the Tennessee Valley Authority balancing authority.

ZP26

The set of delivery points associated with Path 26 on the California transmission grid commonly identified as and agreed to by the counterparties to constitute the ZP26 Hub.


EQR Data Dictionary

Appendix D. Time Zone

Time Zone

Definition

AD

Atlantic Daylight

AP

Atlantic Prevailing

AS

Atlantic Standard

CD

Central Daylight

CP

Central Prevailing

CS

Central Standard

ED

Eastern Daylight

EP

Eastern Prevailing

ES

Eastern Standard

MD

Mountain Daylight

MP

Mountain Prevailing

MS

Mountain Standard

NA

Not Applicable

PD

Pacific Daylight

PP

Pacific Prevailing

PS

Pacific Standard

UT

Universal Time




EQR Data Dictionary

Appendix E. Units

Units

Definition

KV

Kilovolt

KVA

Kilovolt Amperes

KVR

Kilovar

KW

Kilowatt

KWH

Kilowatt Hour

KW-DAY

Kilowatt Day

KW-MO

Kilowatt Month

KW-WK

Kilowatt Week

KW-YR

Kilowatt Year

MVAR-YR

Megavar Year

MW

Megawatt

MWH

Megawatt Hour

MW-DAY

Megawatt Day

MW-MO

Megawatt Month

MW-WK

Megawatt Week

MW-YR

Megawatt Year

RKVA

Reactive Kilovolt Amperes

FLAT RATE

 Flat Rate


EQR Data Dictionary

Appendix F. Rate Units

Rate Units

Definition

$/KV

dollars per kilovolt

$/KVA

dollars per kilovolt amperes

$/KVR

dollars per kilovar

$/KW

dollars per kilowatt

$/KWH

dollars per kilowatt hour

$/KW-DAY

dollars per kilowatt day

$/KW-MO

dollars per kilowatt month

$/KW-WK

dollars per kilowatt week

$/KW-YR

dollars per kilowatt year

$/MW

dollars per megawatt

$/MWH

dollars per megawatt hour

$/MW-DAY

dollars per megawatt day

$/MW-MO

dollars per megawatt month

$/MW-WK

dollars per megawatt week

$/MW-YR

dollars per megawatt year

$/MVAR-YR

dollars per megavar year

$/RKVA

dollars per reactive kilovar amperes

CENTS

cents

CENTS/KVR

cents per kilovolt amperes

CENTS/KWH

cents per kilowatt hour

FLAT RATE

rate not specified in any other units



EQR Data Dictionary

Appendix G. Index Price Publisher

Index Price Publisher Abbreviation

Index Price Publisher

AM

Argus Media

EIG

Energy Intelligence Group, Inc.

IP

Intelligence Press

P

Platts

B

Bloomberg

DJ

Dow Jones

Pdx

Powerdex

SNL

SNL Energy





EQR Data Dictionary

Appendix H. Exchange/Broker Services

Exchange/Brokerage Service

Definition

BROKER

A broker was used to consummate or effectuate the transaction.

ICE

Intercontinental Exchange

NYMEX

New York Mercantile Exchange



1 This version of Appendix B replaces the version that was included with Revisions to Electric Quarterly Report Filing Process, Order No. 770, 141 FERC ¶ 61,120 (2012).

File Typeapplication/msword
AuthorEllen Brown
Last Modified ByEllen Brown
File Modified2012-11-19
File Created2012-11-19

© 2024 OMB.report | Privacy Policy