Long-Term Retardant

Hydration - Viscosity Curves

Technical Data Sheet

(Ref: FSM 5160)


Product Name:

     


Submitting Co.:

     


Formulation Identification:

     


Mix Ratio Range:

     

lb/gal H2O

OR

     

gal/gal H2O (Fill in one blank.)




Provide the data, graphs, or tables listed below for each mix ratio for which evaluation has been requested.1

  1. A graph of mixed retardant viscosity versus time since mixing, at a temperature test of 70 °F (21 °C). At a minimum, include viscosity at 10 minutes, 60 minutes, 4 hours, 8 hours, 24 hours, and 48 hours, after mixing.

  1. A table of mixed retardant viscosity versus temperature of water used for mixing. Viscosity shall be measured at 10 minutes, 1 hour, and 24 hours following mixing. Temperatures of the tap water used for mixing shall be 40 °F (4 °C), 70 °F (21 °C), and 100 °F (38 °C).

  1. A table of mixed retardant viscosity at 70 °F (21 °C), 1 hour and 24 hours following mixing, versus the thickener concentration from 25 percent to 200 percent of the nominal thickener concentration, i.e. if the thickener concentration is 1.0 percent then provide data for 0.25 percent, 0.5 percent, 0.75 percent … up to 2.0 percent.






BURDEN AND NONDISCRIMINATION STATEMENTS

According to the Paperwork Reduction Act of 1995, an agency may not conduct or sponsor, and a person is not required to respond to a collection of information unless it displays a valid OMB control number. The valid OMB control number for this information collection is 0596-0184. The time required to complete this information collection is estimated to average 1.75 hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information.

The U.S. Department of Agriculture (USDA) prohibits discrimination in all its programs and activities on the basis of race, color, national origin, age, disability, and where applicable, sex, marital status, familial status, parental status, religion, sexual orientation, genetic information, political beliefs, reprisal, or because all or part of an individual’s income is derived from any public assistance. (Not all prohibited bases apply to all programs.) Persons with disabilities who require alternative means for communication of program information (Braille, large print, audiotape, etc.) should contact USDA’s TARGET Center at 202-720-2600 (voice and TDD).

To file a complaint of discrimination, write USDA, Director, Office of Civil Rights, 1400 Independence Avenue, SW, Washington, DC 20250-9410 or call toll free (866) 632-9992 (voice). TDD users can contact USDA through local relay or the Federal relay at (800) 877-8339 (TDD) or (866) 377-8642 (relay voice). USDA is an equal opportunity provider and employer.

1 Measure viscosity using a Brookfield rotational viscometer (or equivalent) at 60 rpm. Use spindle 2 for viscosities between 1 and 500 centipoise and spindle 4 for viscosities greater than 500 centipoise.)