OMB Control No: | xxxx-xxxx | |||||||||||||||||||
Expiration Date: | xx/xx/xxxx | |||||||||||||||||||
Review Draft | ||||||||||||||||||||
Facility data for the NEI. | ||||||||||||||||||||
Instruction: | Email address for person providing data | A general descriptive comment on the data | Name of person providing data | Commenter's affiliation - state/local/agency, trade association, company, etc. | Phone number for person providing data | See State and County FIPS tab in Lookups for P&P Survey.xls | Complete if the facility is located in a tribal area. See Tribal Code tab in Lookups for P&P Survey.xls. |
Complete if the facility is located in a tribal area. See Tribal Code tab in Lookups for P&P Survey.xls |
Two-character alphabetical code for state | County name for MACT facility | See State and County FIPS tab in Lookups for P&P Survey.xls | Unique identifier assigned by EPA to NEI Facility Use a temporary ID of "NEW_____" where the blank is your facility's zip code. |
The ID number assigned by the EPA Facility Registry System. FRS IDs can be found at: http://www.epa.gov/enviro/html/facility.html. Limit text to 15 characters. Leave blank if you have difficulty finding this information. |
For the facility code us one of the following: 01 - MAJOR (HAP emitting facility) 02 - Area (HAP emitting facility) |
Definition associated with Facility Category Code | The name of the facility | Physical street address for MACT facility | City where the MACT facility is located | State where MACT facility is located | Zip Code for the MACT facility |
Survey reference: | ||||||||||||||||||||
Field: | Commenter Email Address | Commenter General Comment | Commenter Name | Commenter Organization | Commenter Phone Number | EPA Region | Tribal Code | Tribe Name | State Abbreviation | County Name | State County FIPs | NEI Site ID | Facility Registry Identifier | Facility Category | Facility Category Description | Facility Name | Location Address | City | State | Zip Code |
Example entry: | jane.doe@amymillusa.com | Jane Doe | Anymill USA | 999-999-9999 | 3 | 000 | Non-Tribal Area | VA | Amherst County | 51009 | NEW99999 | 110020689999 | 01 | MAJOR (HAP emitting facility) | Anymill USA | 1000 Plant Road | Anytown | VA | 24553 |
OMB Control No: | xxxx-xxxx | |||||||||||||||||||||||||||||||||||||||||||||
Expiration Date: | xx/xx/xxxx | |||||||||||||||||||||||||||||||||||||||||||||
Review Draft | ||||||||||||||||||||||||||||||||||||||||||||||
Inventory data for the NEI. | ||||||||||||||||||||||||||||||||||||||||||||||
Instruction: | OPTIONAL. Use this column for comments related to emissions. | OPTIONAL. Use this column for comments related to the process. | OPTIONAL. Use this column for comments related to stack configuration. | OPTIONAL. Unique ID number used by a state/local/tribal agency to identify a facility. | Unique identifier assigned by EPA to NEI Facility. Use a temporary ID of "NEW_____" where the blank is your facility's zip code. |
The name of the facility | See the SIC tab in Lookups for P&P Survey.xls | See the SIC tab in Lookups for P&P Survey.xls (Description column) | North American Industry Classification Code. An industry classification system, NAICS is erected on a production-oriented conceptual framework that groups establishments into industries according to similarity in the process used to produce goods or services. See Lookups for P&P survey.xls. |
Enter an Emission Unit ID. This Emission Unit ID will be used throughout all parts of your pulp and paper survey response. Limit text to 6 characters. |
Enter description of the emission unit. Use this field to identify emission units for which SCCs are not available or are assigned generic or "not-elsewhere-classified" SCCs. See the survey instruction document for additional instructions. | OPTIONAL. Enter a Process ID (if an additional ID is needed to sub-chanracterize your emission process). Be sure to note any sub-characterization of your process in the "Emission Unit Description" column. Limit text to 6 characters. |
Source Classification Code. See Lookups for P&P survey.xls and the pulp and paper survey instructions. |
OPTIONAL. Descriptive text associated with SCC code. Copy the SCC description from the "Short name" column in the SCC-related tabs of Lookups for P&P survey.xls if helpful for your purposes. | Add your own ID to indicate the point/location where emissions are released to ambient air. There may be multiple Emission Release Point IDs associated with a single Emission Unit ID (e.g., for emission units with multiple stacks/vents). Limit text to 6 characters. |
The code for physical configuration of the release point: 1 - Fugitive 2 - Vertical 3 - Horizontal 4 - Goose Neck 5 - Vertical with Rain Cap 6 - Downward-facing Vent 99 - Unknown |
OPTIONAL. Descriptive text for EmissionReleasePointType code: 1 - Fugitive 2 - Vertical 3 - Horizontal 4 - Goose Neck 5 - Vertical with Rain Cap 6 - Downward-facing Vent 99 - Unknown |
Start date of the period in which reported emissions occur, e.g., 20090101 = January 1, 2009 | End date of the period in which reported emissions occur, e.g., 20091231 = December 31, 2009 | Code assigned by EPA to individual pollutants. See The Pollutant tab in Lookups for P&P Survey.xls (POLLUTANT_CD column) | Descriptive text associated with pollutant code. See the Pollutant tab in Lookups for P&P Survey.xls (DESCRIPTION column) | Broader grouping to which an individual chemical compound is assigned to by EPA. For example,"lead and compounds" contains all pollutants containing lead. You may leave this column blank (for EPA to fill in) |
Numeric value of routine emissions in tons/year | Use one of the following Emission Calculation Method Codes: 01 - CEMS - CONTINUOUS EMISSION MONITORING SYSTEM 02 - ENGINEERING JUDGMENT 03 - MATERIAL BALANCE 04 - STACK TEST 05 - EPA SPECIATION PROFILE 06 - STATE/LOCAL SPECIATION PROFILE 07 - MANUFACTURER SPECIFICATION 08 - EPA EMISSION FACTOR 09 - STATE/LOCAL EMISSION FACTOR 10 - SITE-SPECIFIC EMISSION FACTOR 11 - VENDER EMISSION FACTOR 12 - TRADE GROUP EMISSION FACTOR Leave this column blank if no code applies and enter a description in the "Emissions Comment" column to the right. |
Enter a comment describing the method for calculating emissions if, for example, one of the Emissions Calculation Method Codes does not apply. | Maximum hourly emission rate for routine emissions. | OPTIONAL. Emissions that occurred during startup periods. | OPTIONAL. Maximum hourly emission rate for startup period emissions. | OPTIONAL. Emissions that occurred during shutdown periods. | OPTIONAL. Maximum hourly emission rate for shutdown period emissions. | Code assigned to Maximum Achievable Control Technology (MACT) regulated sources. See the MACT Code tab in Lookups for P&P Survey.xls. Use the MACT Code listed with the MACT Source Category description. Enter "none" if no MACT category applies. | See the MACT Code tab in Lookups for P&P Survey.xls. Use the MACT Source Category description listed with the MACT Code. | The height (in feet) of a stack | The temperature of an exit gas stream (degree Fahrenheit) | The diameter (in feet) of a stack | The velocity of an exit gas stream (feet per second) | Numeric value of stack gas flow rate in actual cubic feet per second | Dimension of the source in the east-west (x-) direction, commonly referred to as length | Dimension of the source in the north-south (y-) direction, commonly referred to as width | Release angle (clockwise from true North); orientation of the y-dimension relative to true North, measured positive for clockwise starting at 0 degrees (maximum 89 degrees). EPA will assume 0 degrees if it is not provided in data submittal. Note that the fugitive angle is relative to the width of the emission unit. See instructions for details. |
Longitude measured in decimal degrees of the angular distance on a meridian east or west of the prime meridian. Negative (-) data point for N America. Include (-) sign, Ex. -123.234561. For point sources this represents the center of the source; for fugitive sources this is the southwest corner if the fugitive angle is zero, or the western most corner if the fugitive angle is greater than zero. | Latitude measured in decimal degrees of the angular distance on a meridian north or south of the equator. Positive (+) data point for N America. Include (+) sign, Ex. +78.123456. For point sources this represents the center of the source; for fugitive sources this is the southwest corner if the fugitive angle is zero, or the western most corner if the fugitive angle is greater than zero. | North American Datum (NAD) for longitude and latitude coordinates (NAD27 or NAD83). If left blank NAD83 is assumed. | Select the most representative control measure code from Lookups for P&P Survey.xls. Codes for some common controls are as follows: 127 - Fabric Filter 128 - Electrostatic Precipitator 131 - Thermal oxidizer 141 - Wet scrubber 146 - Wet Electrostatic Precipitator 150 - Mechanical Collector |
Provide control measure description from Lookups for P&P Survey.xls. If you cannot find a representative control measure code from Lookups for P&P Survey.xls, then write in a description of the control measure in this column. |
OPTIONAL: Use this column if you need to describe a control that is not identified in the codes list and/or to indicate backup controls. |
Survey reference: | ||||||||||||||||||||||||||||||||||||||||||||||
Field: | Comment-Emissions | Comment-Process | Comment-Stack | State Facility Identifier | NEI Site ID | Facility Name | SIC Code | SIC Code Description | NAICS Code | Emission Unit ID | Emission Unit Description | Process ID | SCC | SCC Description | Emission Release Point ID | Emission Release Point Type | Emission Release Point Type Description | Start Date | End Date | Pollutant Code | Pollutant_Code_Desc | HAP_CATEGORY_NAME | Routine Emissions (TPY) | Emission Calculation Method Code | Emissions Comment | Routine Emissions Max Hourly Rate (lbs per hour) | Startup Emissions (TPY) | Startup Emissions Max Hourly Rate (lbs per hour) | Shutdown Emissions (TPY) | Shutdown Emissions Max Hourly Rate (lbs per hour) | MACT Code | MACT Source Category | Stack Height (ft) | Exit Gas Temperature (F) | Stack Diameter (ft) | Exit Gas Velocity (ft/sec) | Exit Gas Flow Rate (cuft/sec) | Fugitive Length (E-W) (ft) | Fugitive Width (N-S) (ft) | Fugitive Angle (degrees) | Longitude (decimal degrees) | Latitude (decimal degrees) | North American Datum | Control measure code | Control Measure Code Description | Control Measure Comment |
Example entry: | 00022 | NEW99999 | Anymill USA | 2631 | Paper And Allied Products, Paperboard Mills, Paperboard mills | 322130 | 1 | BLR01 B&W (NORTH) BOILER | 1 | 10200401 | Ext Comb /Industrial /Residual Oil /Grade 6 Oil | 1 | 02 | Vertical | 20090101 | 20091231 | PM10-FIL | Primary PM10, Filterable Portion Only | PM | 0.314416647 | 04 | 0.31 | 0.51 | 0.68 | 0.23 | 0.52 | 0107-3 | Industrial/Commercial/ Institutional Boilers & Process Heaters - oil | 100 | 400 | 9 | 19.4200000762939 | 1235.19995117188 | -78.9104537963867 | 37.5106315612793 | NAD83 | 128, 129 | Electrostatic Precipitator, Scrubber | ESP is followed by a scrubber | |||||||
00023 | NEW99999 | Anymill USA | 2631 | Paper And Allied Products, Paperboard Mills, Paperboard mills | 322130 | 1 | BLR01 B&W (NORTH) BOILER | 1 | 10200401 | Ext Comb /Industrial /Residual Oil /Grade 6 Oil | 1 | 02 | Vertical | 20090101 | 20091231 | 50000 | Formaldehyde | Formaldehyde | 0.000375 | 12 | Similar source emission factor (derived from a similar emission unit at a different mill within the company) | 9E-05 | 0.0009 | 0.000205479452055 | 0.00005 | 1.14155251141553E-05 | 0107-3 | Industrial/Commercial/ Institutional Boilers & Process Heaters - oil | 100 | 400 | 9 | 19.4200000762939 | 1235.19995117187 | -78.9104537963867 | 37.5106315612792 | NAD83 | 128, 129 | Electrostatic Precipitator, Scrubber | ESP is followed by a scrubber | |||||||
00022 | NEW99999 | Anymill USA | 2631 | Paper And Allied Products, Paperboard Mills, Paperboard mills | 322130 | 2 | Lime kiln | 1 | 30700106 | Sulfate (Kraft) Pulping /Lime Kiln | 1 | 02 | Vertical | 20090101 | 20091231 | 75070 | Acetladehyde | Acetaldehyde | 1.678 | 08 | 0.41 | 0.78 | 0.181395348837209 | 0.78 | 0.181395348837209 | 0107-3 | 106 | 350 | 7.5 | 21 | 956.8 | -78.818652902 | 37.49799671 | NAD83 | 129 | Scrubber |
File Type | application/vnd.ms-office |
Last Modified By | EPA |
File Modified | 2011-02-09 |
File Created | 2009-09-20 |